3M C3266PW Manuel D’Utilisation

Page de 56
38 
 
3M™ Multi-Touch Chassis Display User Guide 
 
3M Touch Systems, Inc. Proprietary Information – TSD-39373 REV E 
Set Feature - Reset  
This is a request to perform a controller reset. Soft resets are automatic after any block 
parameter changes. 
Table 11. Reset - Setup Stage 
Offset  Field 
Size 
Value 
Description 
bmRequestType 
0x21 
Class,H2D,Interface 
bRequest 
0x09 
Set Report 
wValue 
0x0303 
msb=03=Feature  
lsb=03= Feature Report ID  
wIndex 
Always 0 
wLength 
Always 8 
Table 12. Reset – Data Stage 
Offset  Field 
Size 
Value 
Description 
Report ID 
0x03 
Feature Report ID 
Report Subtype 
1  
0x07 
Indicates a reset request 
bResetType 
0x01 
0x02 
Soft Reset 
Hard Reset 
3--7 
 
Not used 
A Hard Reset will cause the controller to re-enumerate. 
In the case of a Soft Reset, after sending the command, the controller will acknowledge 
(ACK) the transfer, but the command will not yet be completed. Before sending any 
other commands, the host should poll with GetStatus until the command status field 
returns “Soft Reset Occurred,” “Command Complete,” or “Fail”.  Any timeout for this 
status polling should be 2 seconds minimum. 
Set Feature –Restore Defaults 
This is a request to restore parameter defaults. 
Table 13. Restore Defaults -- Setup Stage 
Offset  Field 
Size 
Value 
Description 
bmRequestType 
0x21 
Class,H2D,Interface 
bRequest 
0x09 
Set Report 
wValue 
0x0303  msb=03=Feature  
lsb=03= Feature Report ID  
wIndex 
Always 0 
wLength 