18954-0-0705
INSTALLING AS A VENTED APPLIANCE
Notice  (Damper Clamp Installation)
When installing your log set as a vented installation the damper 
clamp must be used.
When installing your log set as a vent-free installation the damper 
clamp can be used to eliminate the potential for odors when burn-
ing the logs for the first time.
Installing Damper Clamp (Figure 9) 
Remove  all  ashes  or  other  debris  from  the  fireplace.  If  the 
fireplace is equipped with an ash dump be sure to seal the door 
with furnace cement or high temperature silicone. Be sure to 
check the damper for proper operation and verify that the flue 
passageway is open.
Place the clamp over the lip of the damper and tighten the hold 
down bolt until the clamp is securely attached to the damper. This 
will prevent the damper from accidentally closing. 
Manual and millivolt controlled gas logs may be installed as a 
vented decorative log set in compliance with ANSI Z21.60 and 
National Fuel Gas Code. When the gas logs are operated with the 
damper open, non-combustible material and minimum mantel 
requirements do not apply.
BEFORE FULLY INSTALLING THE APPLIANCE
•  Turn off the gas supply to the fireplace or firebox.
•  Seal any fresh air vents and/or ash clean-out doors located on 
the floor or wall of the fireplace. If left unsealed, drafting may 
cause pilot outage or sooting. Use a heat resistant sealant. Do 
not seal the chimney flue damper.
Before installing in a solid fuel burning fireplace, the chimney 
flue and firebox must be cleaned of soot, creosote, ashes and loose 
paint by a qualified chimney cleaner.
You must secure the gas log heater to the fireplace floor. If 
not, the entire unit may move when you adjust the controls. 
Movement of unit may cause shifting of the gas logs which 
leads to sooting and improper burning. Grate movement could 
cause a gas leak.
Special care is required if you are installing the unit into a 
sunken fireplace. You must raise the fireplace floor to allow 
access to gas log controls. This will insure adequate air flow 
and guard against sooting. Raise the fireplace floor using 
noncombustible materials.
Assembly Procedure: (Figure 10)
1. Center the gas log unit in the fireplace or firebox. Make certain 
the front feet of the grate sit inside the front edge of the
  fireplace or firebox.
2. An anchor hole is provided in the two bottom side members of 
the grate frame. After centering the grate correctly, mark the 
hole positions on the fireplace/firebox floor. Drill two (2) 5/32" 
diameter holes approximately 1-1/2" deep for masonry screws 
or 1/8" hole for sheet metal screws.
3. Anchor the grate to the fireplace/firebox floor using the screws 
provided. Refer to Figure10. 
Proper installation of the grate is essential to prevent any move-
ment of the gas logs and controls during operation.
Figure 10
Figure 9