Empire Comfort Systems DVP42FP Manuel D’Utilisation

Page de 72
21759-6-0608
Page 12
DVP42 DVP48
"A" 37 3/4" 37 3/4"
"B" 43 3/8" 49 3/8"
"C" 19 7/8" 19 7/8"
Figure 11
Attention: If a base or mantel is not used and the appliance is 
installed directly on carpeting, tile or other combustible material 
other than wood flooring, it shall be installed on a metal or wood 
panel extending the full width and depth of the appliance. The 
vertical dimension in Figure 11 must be adjusted when a metal or 
wood panel is placed beneath the appliance.
Finishing (Figures 12 and 13)
Finish  the  walls  with  the  material  of  your  choice.  Figure  3  on 
page 8  shows the minimum vertical and corresponding maximum 
horizontal dimensions of mantels or other combustible projections 
above the top front edge of the fireplace.
Only non-combustible materials may be used to cover the black 
fireplace front.
Warning: When finishing the fireplace never obstruct or 
modify the air inlet/outlet louvers in any manner. Provide 
adequate clearances around air openings into the combustion 
chamber.
Caution: If the joints between the finished wall and the fireplace 
surround  (top  and  sides)  are  sealed,  a  300°F  minimum  sealant 
material must be used. These joints are not required to be sealed. 
Only non-combustible material (using 300°F minimum adhesive if 
needed), can be applied as facing to the fireplace surround.
Flush Mount Mantel Installation (Figure 10)
The fireplace must extend 3/4" beyond finished wall surface when 
using a flush mount mantel. Refer to Figure 10 to locate nailing 
flanges on fireplace sides. Mark and drill two (2) 1/8" holes into 
fireplace  side  to  mount  each  nailing  flange.  Use  eight  (8)  1/2" 
hex-head screws supplied in hardware package to attach nailing 
flanges to fireplace sides.
Figure 10
Framing (Figure 11)
Fireplace framing can be built before or after the fireplace is set in 
place. Framing should be positioned to accommodate wall covering 
and  fireplace  facing  material.  The  fireplace  framing  should  be 
constructed of 2 x 4 lumber or heavier. The framing headers may 
rest on the fireplace standoffs. Refer to Figure 11 for minimum 
framing dimensions.
CAUTION:  MEASURE  FIREPLACE  DIMENSIONS AND 
VERIFY FRAMING METHODS, AND WALL COVERING 
DETAILS  BEFORE  FRAMING  CONSTRUCTION 
BEGINS.
Framing dimension "A" includes a three inch clearance for 
standoffs on firebox. After installing firebox into framing, 
the finished wall surface must cover the three inch opening 
above the firebox.
NAIL OR OTHER SUITABLE FASTENER
INSTALLATION (continued)