Empire Comfort Systems DVP42FP Manuel D’Utilisation

Page de 72
21759-6-0608
Page 17
MAXIMUM HORIZONTAL
RUN WITH NO VERTICAL
RISE AND 90° ELBOW
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
minimum
Figure 25
Figure 24
MINIMUM    HOLE  LOCATION  DIMENSIONS  FOR 
THROUGH THE WALL HORIZONTAL INSTALLATIONS 
WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent 
termination will be centered (if possible) between two (2) studs. This 
will avoid any extra framing. All vent kit pipes should be assembled 
on the unit after the unit is moved into the final position.
Cutting the Hole (Figures 23)
After the fireplace has been positioned in its permanent location, 
the hole through the exterior wall of the house can be cut. This hole 
must be 12" (305mm) high x 10" (254mm) wide with its center line 
determined by the amount of vertical rise and horizontal run of the 
termination. See Figure 23. When locating the hole it must be noted 
that the bottom of the cap must be 12" (305mm) above the ground 
level, and top of the cap must be no less than 18" (457mm) below 
a combustible projection, and no closer than 9" (229mm) to any 
wall running parallel to vent termination. See Figure 24.
A
CENTER OF
ELBOW
STRAIGHT
OUT
(MINIMUM)
2
30
FIREPLACE
SERIES
HARD ELBOW DIMENSIONS
"A"
"B"
"C"
DVP42FP
43-1/2"
(1105mm)
5" 
(127mm)
 7" 
(178mm)
DVP48FP
43-1/2"
(1105mm)
5" 
(127mm)
 7"
 (178mm)
FIREPLACE
SERIES
FLEX PIPE 90 DEGREE BEND
"A"
"B"
"C"
DVP42FP
46"
(1143mm)
5" 
(127mm)
 7" 
(178mm)
DVP48FP
46"
(1143mm)
5" 
(127mm)
7"
 (178mm)
Figure 23