1.  Unpack  vent  components  and  check  all  items  for  shipping 
damage.
2.  For this venting system to operate as designed it is depen-
dent on the use of all parts and procedures detailed in these 
instructions. Failure to follow these instructions may poten-
tially affect the performance of this vent system and the at-
tached appliance.
3.  As per the fireplace manufacturer’s instructions, replace the 
existing 6 5/8” diameter fireplace vent adapter with the 7” 
diameter flex vent fireplace adapter included in the vent kit. 
Install the adapter collar with the screws removed from the 
standard fireplace collar. Refer to the fireplace manual for ad-
ditional information on the vent collar removal and installa-
tion.
4.  Once  the  fireplace  location  has  been  determined,  mark  the 
ceiling where the flex vent will pass through. Cut an opening 
for installation of the firestop thimble assembly. The open-
ing must measure a minimum of 9-1/2” x 9-1/2” square. See 
Figure 32.
5.  Next, determine the location for the cutout in the roof open-
ing. This opening must be large enough to provide a mini-
mum 1” air space clearance from the vertical vent pipe to any 
combustible framing.
6.  Install the Firestop/Thimble assembly to the framed opening 
in the ceiling using common nails or screws. 
 
 
Note:  The  thimble  assembly  is  adjustable  up  or  down  as 
needed within the firestop. It is also designed with a pivoting 
firestop for use with 0 - 3/12 pitch cathedral ceilings.
7.  To begin vent system assembly, first layout all the vent com-
ponents on the floor in the order in which they will be as-
sembled.
8.  Stretch the 4” diameter inner flex flue and 7” diameter outer 
flex vent to the maximum length of 6 feet.
9.  Install  the  spring  spacers  provided  around  the  4”  diameter 
flex flue at 1 foot intervals, then slide the flue pipe with spac-
ers into the 7” diameter outer flex vent pipe. Make sure the 
springs are spaced evenly starting at 12 inches from the fire-
place collar. See Figure 33.
NAILS
(4) REQ'D.
THIMBLE
FIRESTOP
CEILING FRAMING
9½” Min.
(241mm)
9½” Min.
(241mm)
NOTE: ADDITIONAL
HOLES FOR ADJUSTING
THIMBLE UP OR DOWN
AS NEEDED
FLEX OUTER
AIR INTAKE PIPE
SPACER SPRINGS
FLEX FLUE PIPE
Figure 32
Figure 33
SPACER SPRINGS
4" FLEX
VENT PIPE
12”
305mm
12”
305mm
12”
305mm
12”
305mm
Step-By-Step Installation For Flex DV Kit
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.)