Empire Comfort Systems DVP42FP Manuel D’Utilisation

Page de 72
21759-6-0608
Page 51
1.  To wire Junction Box Receptacle, remove the tab on the side of 
the receptacle (hot side) to split receptacle. This will be required 
to separate blower and valve circuits.
2.  Power for switched and live sides of Duplex Receptacle must 
come from the same power source. (One circuit breaker on main 
panel must switch all power off.)
3.  From the wall box to the fireplace a 3-wire conductor with 
ground  is  recommended,  however  (2)  two-wire  conductors 
with grounds may be used in place of a 3-wire conductor with 
a ground if the black wires from the thermostat and blower 
switch are identified. 
4.  Two wall switches, or a wall switch and thermostat may be used 
to activate the two receptacle plugs independently.
The intermittent pilot (120/24 volt system) is ON when the main 
burner is ON. When the main burner is OFF the intermittent pilot 
is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13mm) of 
the tip of the flame rod.
To adjust:
1. Remove the pilot adjustment cover screw.
2. Turn  the  inner  adjustment  screw  clockwise 
  to  
decrease  or  counterclockwise 
  to  increase  pilot 
flame.  Pilot  adjustment  is  shipped  at  full  flow  rate.  Turn 
the  inner  adjustment  screw  clockwise
  if  the  inlet  
pressure is too high.
3. Replace the cover screw after the adjustment to prevent gas 
leakage.
Label all wires prior to disconnection when servicing controls. 
Wiring  errors  can  cause  improper  and  dangerous  operation. 
Verify proper operation after servicing.
Provided on the intermittent pilot wiring harness are two (2) stripped 
and bare wires that are labeled THERMOSTAT. The wires will be 
used for attachment of 24 volt thermostat, optional FWS-1 wall 
switch  or  will  attach  into  the  receiver  on  an  optional  FRBC-1, 
FRBTC-1 or FREC-1 remote control.
Installation of Remote Receiver 
Place remote receiver on the floor of fireplace behind the louver 
as far forward as possible.
Attention: The velcro loop and hook are not necessary in this 
installation but can be used to secure remote receiver.
Figure 83
ELECTRICAL CONNECTION (Figure 84)
The DVP Intermittent Pilot Models with optional fan requires 120 
VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 70, if an external 
electrical source is utilized. 
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-
FIED  ELECTRICIAN AND  SHALL  BE  IN  COMPLIANCE 
WITH ALL LOCAL, CITY AND STATE BUILDING CODES. 
BEFORE  MAKING  THE  ELECTRICAL  CONNECTION, 
MAKE  SURE THAT  MAIN  POWER  SUPPLY  IS  DISCON-
NECTED. THE APPLIANCE, WHEN  INSTALLED,  MUST 
BE  ELECTRICALLY  GROUNDED  IN  ACCORDANCE 
WITH  LOCAL  CODES  OR,  IN  THE ABSENCE  OF  LO-
CAL CODES, WITH THE NATIONAL ELECTRICAL CODE  
ANSI/NFPA 70 (LATEST EDITION).
Figure 84
INTERMITTENT PILOT OPERATING INSTRUCTIONS
INTERMITTENT PILOT WIRING DIAGRAM