Figure 3 - Typical Installations
Note:  When the unit is installed with one side flush 
with a wall, the wall on the other side of the unit must 
not extend beyond the front edge of the unit.
COLd CLImATE INSULATION
For cold climate installations, seal all cracks 
around  your  appliance  with  noncombustible 
material  and  wherever  cold  air  could  enter 
the room. It is especially important to insulate 
outside chase cavity between studs and under 
floor on which appliance rests, if floor is above 
ground level.  Gas line holes and other open-
ings should be caulked or stuffed with unfaced 
fiberglass insulation.  
If the fireplace is being installed on a cement 
slab in cold climates, a sheet of plywood or 
other raised platform can be placed underneath 
to prevent cold transfer to the fireplace and into 
the  room.    It  also  helps  to  sheetrock  inside 
surfaces and tape for maximum air tightness 
and caulk firestops.
mANUFACTUREd HOmE 
REQUIREmENTS
This appliance may be installed in an aftermarket 
permanently located, manufactured home and 
must be installed in accordance with the manu-
facturer's instructions and the Manufactured 
Home Construction and Safety Standard, Title 
24 CFR, Part 3280, in the United States, or the 
Standard for Installation in Mobile Homes, CAN/
CSA Z240 MH Series, in Canada. 
Cet appareil peut être installé cómme du matéri-
el d'origine dans une maison préfabriquée (É.U. 
seulement) ou mobile et doit être installé selon 
les instructions du fabricant et conformément 
à la norme Manufactured Home Constructions 
and Safety, Title 24 CFR, Part 3200 aux Unis ou 
à la norme Can/CSA-Z240 Série MM, Maisons 
mobiles au Canada. 
This appliance is only for use with the type of gas 
indicated on the rating plate.  This appliance is 
not convertible for use with other gases, unless 
a certified kit is used.
Cet appareil doit être utilisé uniquement avec le 
type de gaz indiqué sur la plaque signalétique.  
Cet appareil ne peut être converti à d'autres gaz, 
sauf si une trousse de conversion est utilisée.
CAUTION:  Ensure  that  the  cross  mem-
bers  are  not  cut  or  weakened  during 
installation.  The  structural  integrity  of 
the manufactured home floor, wall, and 
ceiling / roof must be maintained. 
CAUTION: This appliance must be ground-
ed  to  the  chassis  of  the  manufactured 
home in accordance with local codes or 
in the absence of local codes, with the 
National Electrical Code ANSI / NFpA 70 
- latest edition or the Canadian Electrical 
Code CSA C22.1 - latest edition. 
Notes:
•  An  Outside  Combustion  Air  Hook-Up  Kit 
must be installed (see Step 7, Page 15).
LOCATION
In  selecting  the  location,  the  aesthetic  and 
functional  use  of  the  appliance  are  primary 
concerns.  However,  vent  system  routing  to 
the exterior and access to the fuel supply are 
also important.  
Due  to  high  temperatures,  the  appliance 
should be located out of traffic and away from 
furniture and draperies (Figure 3). 
En raison des températures élevées, l’appareil 
devrait être installé dans un endroit où il y a 
peu de circulation et loin du mobilier et des 
tentures (Figure 3).
The location should also be free of electrical, 
plumbing  or  other  heating/air  conditioning 
ducting.
Be  aware  that  this  is  a  heat  producing  ap-
pliance.  Objects  placed  above  the  unit  are 
exposed to elevated temperatures.
do not insulate the space between the appli-
ance and the area above it.
The  appliance  should  be  mounted  on  a  fully 
supported  base  extending  the  full  width  and 
depth of the unit. The appliance may be located 
on or near conventional construction materials. 
However, if installed on combustible materials, 
such  as  carpeting,  vinyl tile,  etc.,  a  metal  or 
wood barrier covering the entire bottom surface 
must be used.
Offset 
Venting
Vertical 
Venting
Shown with Outside Air Kit  
installed (model FOAK-4 or 
FOAK-4Ld)