Therma-Stor Products Group D385 Manuel D’Utilisation

Page de 7
2
www.usephoenix.com • sales@thermastor.com
Toll-Free 1-800-533-7533
1 Specifications
Part No. 
4026700
Power 
2 circuits:  Amps, 5 VAC each 
 
22 Amps total power consumption
Water 
6 pints per day AHAM 
Removal
Blower 
385 CFM Process Airflow 
 
75 CFM Reactivation Airflow
Operating  
Up to 40°F  
Range   
As low as 0°F
Filters 
Process filter size: 6” x 20” x 2”
 
Reactivation filter size: 2” x 2” x ”
 
Duct  
Process Inlet: 2” Flex-Duct (optional) 
Connections  Process Outlet: 0” Lay Flat collar (optional)
 
Reactivation Inlet: 6” Flex-Duct (optional) 
 
Reactivation Outlet: 6” Flex-Duct (required)
 
  
Warranty 
One year Parts and Labor
Dimensions:
 
Machine 
Shipping
Width 
24-/4” 
27-/2”
Height 
40” 
45-/2”
Depth 
2-3/8” 
22”
Weight 
05 Lbs. 
30 Lbs.
Popular Accessories
4026859 
6” Metalized Polyester Flex-Duct 25’ (Standard) 
402028 
6” Insulated Flex-Duct 25’
4024750  
2” Metalized Polyester Flex Duct 25’
4022537 
0” Lay Flat Duct 500’
4024935 
0” Lay Flat Duct 250’
4024440  
Kestrel 3000  Multi-Function Air Meter
Process Air Filter Replacement
402475    6” x 20” x 2” MERV  Filter (Standard)
4024969    6” x 20” x 2” MERV 6 Filter (Optional)
402264    6” x 20” x 2” MERV 4 Filter (Optional)
Reactivation Air Filter Replacement
402635    2” x 2” x ” MERV 7 Filter (Standard)
Read the operation and maintenance instructions carefully 
before using this unit.
Proper adherence to these instructions is essential to  
obtain maximum benefit from your Phoenix D385 
dehumidifier. 
Table of Contents
Introduction ................................................................ 
1.   Specifications ........................................................2
2.   Operation .............................................................3
 
2. How The Phoenix D385 Works ..........................3
 
2.2 Avoiding Secondary Damages ...........................3
 
2.3 Universal Use Set-Up .......................................3
 
2.4 Location .........................................................4
 
2.5 Electrical Requirements ...................................4
 
2.6 Control Panel ..................................................4
 
   2.6A Power Switch ............................................4
 
   2.6B Pilot Light ................................................4
 
   2.6C Hour Meter ..............................................4
 
2.7 Ducting Connections........................................4
 
2.8 Storage and Transportation ..............................5
3.   Maintenance .........................................................5
 
3. Air Filter Replacement......................................5
4.   Service .................................................................5
 
4. Warranty .........................................................5
5.   Wiring Diagram .....................................................5
6.   Service Parts List ..................................................6
7.  Warranty ...............................................................7
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________