Vermont Casting ANSI Z83.7-2000 Manuel D’Utilisation

Page de 14
Page 2
FWARNING: Not for use with ductwork.
SPECIFICATIONS:
Dyna-Glo Propane Forced Air Construction Heaters
The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14
It is hard to anticipate every use which may be made of this heater. 
CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.
IMPORTANTRead this user's manual carefully and completely before trying to operate or
service this heater. Improper use of this heater can cause serious injury or death from fire,
explosion and carbon monoxide poisoning.
This is a direct-fired forced-air construction heater for either indoor or outdoor use. Its intended use
is primarily the temporary heating of buildings or structures under construction, alteration or repair.
All the products of combustion generated by the heater are forced through the heater and released
into the area being heated. This heater operates at approximately 98%+ combustion efficiency but
still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon
monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide
adequate ventilation could result in poisoning or death.
Model No.
RMC-FA40DLX
RMC-FA40A
-
RMC-FA(50A)
RMC-FA100DLX
RMC-FA100A
RMC-FA150DLX
RMC-FA150A
Input Rating
40,000 Btu/hr
-
30,000 Btu/hr
50,000 Btu/hr
70,000 Btu/hr
100,000 Btu/hr
120,000 Btu/hr
150,000 Btu/hr
Type of Gas
Propane
Propane
Propane
Propane
Gas Supply Pressures 
to Regulator Maximum Cylinder Pressure
Cylinder Pressure
Cylinder Pressure
Cylinder Pressure
Minimum (for purpose 
of Input Adjustment)
5psig
5psig
5psig
5psig
Manifold Pressure
11” W.C.
10” W.C.
9.5” W.C
8” W.C.
Gas Consumption
1.9lbs/hr
3.3lbs/hr
2.3lbs/hr
1.4lbs/h
4.6lbs/hr
3.3lbs/h - 5.6lbs/hr
7lbs/hr
5.6lbs/hr
Electrical Input
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
Amperage
Unload
Load
0.35A
0.63A
0.58A
0.75A
0.6A
0.8A
0.6A
0.8A
Fan
Unload
Load
3550rpm
3000rpm
3570rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
Ignition
Piezo/Manual Spark Continuous Spark
Continuous Spark
Continuous Spark
Spark Gap
0.16”
0.16”
0.16”
0.16”
Size (L x W x H)
18.1” x 7.7” x 12.8” 18.1” x 7.7” x 12.8”  25.12” x 9” x 15.5”
25.12” x 9” x 15.5”
Weight
15.2lbs (6.9kg)
15.2lbs (6.9kg)
22.7lbs (10.3kg)
22.7lbs (10.3kg)