PLUMBING THE HUMIDIFIER:  
5.0    Select  the  nearest  cold  water  pipe  and  install  the  saddle  connector  and 
needle valve, supplied with this unit. 
Use copper tubing only
 
The  needle  valve  is  a  self-piercing  valve  when  installed  on  copper  pipe.  
Follow the instructions supplied with the valve.  
Mount  the  valve  so  that  water  will  come  from  the  top  or  side.  This  will     
reduce the chance of minerals clogging the valve.  
5.1  Follow these compression plumbing tips:  
Lightly  clean  the  tubing  ends  with  fine  sandpaper  before  making  connec-
tions.  
Make  sure  the  tubing  is  fully  inserted  into  the  fitting  before  tightening  the 
compression nut.  
5.2  
IMPORTANT:  After attaching the saddle valve, thoroughly flush the supply 
tubing  to  clear  the  line. 
Otherwise,  debris  could  block  the  water  flow  at  the    
solenoid valve.  
5.3   
IMPORTANT:  To  assist  you  with  cleaning,  note  the  proper  orientation  of 
parts for assembly and disassembly (Figure 4, below).  
5.4  Slide the hex nut over the copper tubing end. Slide the brass ferrule over the 
tubing. Push the end of the tubing into the threaded fitting and slide the hex nut 
up to the fitting. Tighten the nut.  
5.5  Slide the bushing over the tubing; insert the bushing through the humidifier 
wall until it snaps into place.  
5.6  Open  the  needle valve  at the  cold  water  pipe. 
IMPORTANT:  Check  all fit-
tings for leaks.  
MOUNTING THE HUMIDISTAT:  
6.0  
NOTE:  See the installation instructions packaged with the enclosed humidi-
stat (humidity controller). 
 
6.1  
NOTE:  When wiring the unit to a system that has a multi-speed blower mo-
tor, or that uses a motor other than 120 VAC, include the Skuttle A50 Interface 
Relay in your installation.  
HUMIDIFIER CHECKOUT:  
Check the humidifier operation by following these procedures: 
7.0  Turn on the water valve to the humidifier. 
7.1  Turn the humidistat to the “ON” position.  
7.2    Set  the  furnace  thermostat  high  enough  to  allow  the  furnace  to  come  on. 
When  the  furnace  blower  comes  on,  the  humidifier  should  start  spraying 
(provided there is enough heat reaching the humidifier thermostat).  
7.3  Check the humidifier operation by turning the humidistat off, making sure the 
humidifier stops spraying. 
NOTE:  If the humidifier continues spraying, there may 
be an error in wiring. Review the wiring diagram, above. 
 
7.4  Set the furnace thermostat low enough to allow the furnace to shut off. The 
humidifier should stop spraying either before or as the furnace blower shuts off. 
NOTE:  Again, if the humidifier continues spraying, there may be an error in writ-
ing. Consult the wiring diagram. 
 
7.5  If the humidifier shuts off correctly, repeat steps 6.2 through 6.4 at least five 
times. Each time, check to see that no water impinges on ductwork or any part of 
the  heating  system. 
NOTE:  If  water  impingement  or  fallout  could  occur,  you 
must install a suitable drain pan, plumbed with an adequate runoff drain.  
7.6  Set the furnace thermostat to the desired setting.  
7.7  Finally, set the humidistat as recommended in Table 1, on the front of these 
instructions.  
HUMIDIFIER PARTS:  
8.0  Parts may  be  ordered  through your local  heating or  plumbing  dealer.  (See 
Figure 6, right, top).  
8.1  When ordering repair parts, always give the following information:  
Model Number 
Serial Number (if possible)  
Part Number (See Table 3, right.)  
Part Name 
 
 
PARTS LIST 
 
HOMEOWNER HUMIDIFIER TIPS:  
9.0  If the mineral content of the water in your home is above normal, a lime dust 
may  form  in  the  duct  distribution  system,  as  well  as  in  your  living  areas.  Even 
though these lime  deposits may  adhere to  the  sides  of  your  ductwork, they  will 
not significantly affect air distribution. 
9.1  In a home that has had little or no humidification, a new humidifier may op-
erate almost continuously to attain the desired level of relative humidity. This is 
because furniture, woodwork carpeting, plaster and houseplants will absorb the 
newly-produced humidity to reach normal moisture levels. This period of adjust-
ment will take approximately three weeks.  
9.2  Natural drafts in the home can cause humidified air to escape through open 
fireplace dampers. Make sure they are closed when not in use.  
9.3    When  the  weather  turns  warmer,  humidification  is  unnecessary. 
IMPOR-
TANT
: Turn  the water  and  electrical  power to your  humidifier ‘OFF”  after 
each heating season.  
9.4  When water frequently flows through your humidifier, the nozzle and/or sole-
noid  valve  can  become  clogged  by  lime  and  other  mineral  deposits,  thereby  
diminishing  humidification  effectiveness.  When  this  occurs,  you  should  replace 
the  affected  part(s). 
NOTE: 
It’s  a  good idea to  replace the  spray  nozzle  at the 
start of each heating season to help ensure continuous, trouble-free operation of 
your humidifier. 
(You may wish to have your heating or plumbing contractor per-
form this service for you.)  
9.5    The  inline  water  filter  should  be  cleaned  at  the  end  or  beginning  of  each 
heating season. To do so, loosen the hex nut (see Figure 4, left, top), slide the 
tubing out of the tube connector and remove the filter. At this time, the solenoid 
valve may be disassembled for cleaning.  
9.6  
IMPORTANT: For parts and service, contact your local authorized dealer. 
 
CAUTION:  If  excessive  moisture  appears  on  windows  or  walls,  reduce  the    
humidity  setting  on  your  humidistat  enough  to  eliminate  condensation.  If  the 
situation continues, turn off the water valve that permits water flow to the humidi-
fier, and contact your heating or plumbing contractor.  
Key No. 
Part No. 
Description 
Qty. 
000-1715-013 
Mounting Panel 
A00-0641-099 
Front Panel Assembly 
000-0431-019 
Thermostat 
(592-22 only)
 
A00-1319-034 
Drain Basin Assembly 
000-0814-070 
Indicator Light, 24-Volt 
000-1106-018 
(Part no. varies w/size) 
.50 Gal. Nozzle 
(Consult whlslr. for available sizes) 
000-1319-055 
Nozzle Body 
000-1319-054 
45° Street Elbow 
A01-0814-148 
Solenoid Valve, 24-Volt 
(includes Key Nos. 10 & 12) 
10 
000-1319-070 
90° Street Elbow 
11 
000-1154-000 
Tubing Connector 
12 
000-1319-051 
Inline Filter 
13 
A00-1128-005 
Self-Piercing Valve 
14 
SK0-0055-001 
Humidistat 24-Volt Wall or Duct 
Mounting 
Table 3
 
NOTES 
Figure 4
 
Figure 6
 
Wiring Diagram / Figure 5