FRU Codes:
If an error is detected by the diagnostic
tests, a
 four-digit
 FRU code is displayed. The FRU code
indicates two suspected FRUs. Replace the FRU that is
indicated by the 
two leftmost digits
 first, then replace the
FRU indicated by the
 two rightmost digits
. No FRU is
assigned to code 00. If only one FRU is suspected, the
other FRU code is filled with zeros. See the referenced
page before replacing the FRU.
If the problem remains after replacement of the FRUs, go
to “Undetermined Problems” on page 116.
FRU Code
FRU/Action
10
System Board
11
CPU Card
20
Memory
(See “Memory Checkout” on page 97.)
30
Reserved
32
External Keyboard
33
External Mouse
40
LCD Assembly
45
External CRT
50
1. Reseat the Diskette Drive (FDD-1)
2. Diskette Drive (FDD-1)
51
1. Reseat the Diskette Drive (FDD-2)
2. Diskette Drive (FDD-2)
60
1. Reseat the Hard Disk Drive (HDD)
2. Hard Disk Drive (HDD)
72
PCMCIA Slot Assembly
90
CD-ROM Drive
Checking the Installed Devices List
If a device is installed but the icon appears in a gray shade
rather than a dark shade on the basic diagnostics screen,
the device is defective. Reseat the device connectors. If
the symptom remains, replace the device or the system
board. If needed, adjust the contrast control to clearly
distinguish the shade of the icon.
If a device that is not installed appears in a dark shade (for
example, FDD-2 appears in a dark shade when 
no
 second
FDD is installed), do the following:
1. Replace the first device in the configuration, such as
the FDD-1.
2. If the problem remains, replace the system board.
The PCMCIA, Parallel, and Serial icons are always
displayed in a dark shade because the icons represent
subsystems of the system board and not the actual
attachment of the devices.
   
ThinkPad 365X, 365XD (2625)
123