IBM 380 (2635) Manuel D’Utilisation

Page de 630
      
 
(+)
(-)
Black
Red
Ÿ
If the voltage is correct, replace the system board.
Ÿ
If the voltage is not correct, the backup battery has
been discharged. Replace the backup battery.
Ÿ
If the backup battery discharges quickly after
replacement, replace the system board.
Checking the Standby Battery
1. Power-off the computer and unplug the AC Adapter
from the computer.
2. Open the keyboard, and remove the diskette
drive/CD-ROM drive, the battery pack, and the hard
disk drive.
3. Remove the top cover and keyboard unit.
4. Open the keyboard unit; then remove the keyboard
card.
5. Remove the standby battery from the keyboard card.
(Refer to “1200 Backup Battery, Speaker, Standby
Battery” on page 425 to remove the battery.)
Warning: Be careful not to cause a short circuit when
measuring the voltage.
6. Measure the voltage of the standby battery.
Ÿ
If the voltage between red and black is 3.5 V dc
or greater, the voltage is correct. Go to step 12
on page 355 to verify standby battery operation.
Wire
Voltage (V dc)
Red
+
2.5 to 
+
3.7
Black
Ground
354
IBM Mobile Systems - ThinkPad HMM Volume 3