Storing 6 channel DSD on a 24 track 16/44.1 PCM Recorder
To 24 channel
44.1kS/s
16 bit recorder
PUSH
Analogue
CH1(L)
CH2(R)
Sensitivity
CH1(L) CH2(R)
Digital I/O
Reference In
Reference Out
AES1
AES2
AES3
AES4
CH1
CH2
In
Out
SDIF-2/DSD
75R
Clk
Remote
In
Out
MAINS FUSE 2A(T) ON OFF
PUSH
PUSH
dCS 904
CH2
CH1
Analogue source
MASTER
PUSH
Analogue
CH1(L)
CH2(R)
Sensitivity
CH1(L) CH2(R)
Digital I/O
Reference In
Reference Out
AES1
AES2
AES3
AES4
CH1
CH2
In
Out
SDIF-2/DSD
75R
Clk
Remote
In
Out
MAINS FUSE 2A(T) ON OFF
PUSH
PUSH
dCS 904
CH4
CH3
Analogue source
SLAVE
PUSH
Analogue
CH1(L)
CH2(R)
Sensitivity
CH1(L) CH2(R)
Digital I/O
Reference In
Reference Out
AES1
AES2
AES3
AES4
CH1
CH2
In
Out
SDIF-2/DSD
75R
Clk
Remote
In
Out
MAINS FUSE 2A(T) ON OFF
PUSH
PUSH
dCS 904
CH6
CH5
Analogue source
SLAVE
Figure 8 – Six channel DSD recording on a 24 track 16/44.1 kS/s recorder
Make sure
DSD 4
is turned on, from the menu. The top dCS 904 needs to have
its
Ref In
option set to
Int
. The middle one should be set to
Loop
, and the
bottom one should be set to
Loop.t
The units self align quite accurately (see
on page 37 onwards). Alternatively, word clock may be
used as the syncing method, with no special set ups.
P3D option only:
do this:
Set
DSD
to
DSD 4
, set
AES O
to
On