Panasonic WV-CU161 Manuel D’Utilisation
8
■
Rear View
POWER
OFF
SIGNAL GND
ON
CAMERA
IN
RS485
ALARM
DATA
TERM
VIDEO
OUT
RESET OUT
ALARM IN
RECOVER IN
ALARM OUT
ALARM IN
LINE
COAX
RS485
4
2
ON
OFF
1
2
G
3
4
R
T
A
B
A
B
G
q
w
o
i
!0
!1
!2
!3
!4
!5
u
r
t
e
y
q
Alarm Input Terminal (ALARM IN)
Accepts the alarm signals from external devices such
as alarm sensor when the alarm switch y is in the
upper position.
as alarm sensor when the alarm switch y is in the
upper position.
w
Alarm Output Terminal (ALARM OUT)
The alarm output signal is provided at this terminal for
the Time Lapse VCR etc. when the alarm switch y is in
the upper position.
(Open collector output, 16 V DC or less, 100 mA or
less)
the Time Lapse VCR etc. when the alarm switch y is in
the upper position.
(Open collector output, 16 V DC or less, 100 mA or
less)
e
Ground Terminal (G)
r
Recover Input Terminal (RECOVER IN)
Accepts the alarm recover signal from the Time Lapse
VCR etc. when the alarm switch y is in the upper posi-
tion.
VCR etc. when the alarm switch y is in the upper posi-
tion.
t
Reset Output Terminal (RESET OUT)
When the Alarm Reset Switch is pressed or the Recover
Input Terminal r is input to reset the activated alarm,
and the alarm switch y is in the upper position, the
alarm reset signal for the peripherals is provided at this
terminal.
Input Terminal r is input to reset the activated alarm,
and the alarm switch y is in the upper position, the
alarm reset signal for the peripherals is provided at this
terminal.
y
Alarm Switch (ALARM IN)
Used to select the alarm mode.
When this switch is in the lower position, the terminals
q
When this switch is in the lower position, the terminals
q
,
w
,
r and t above are used for alarm inputs 1 - 4.
u
RS-485 Terminal
This terminal is used to exchange control data with the
camera site.
camera site.
i
Termination Switch (TERM ON/OFF)
This switch is used to terminate the RS-485 terminal.
Normally, keep it in the ON position.
Normally, keep it in the ON position.
o
Line Selection Switch (LINE 4/2)
This switch is used to select either Full-duplex (4-lines)
or Half-duplex (2-lines) for the communication lines.
or Half-duplex (2-lines) for the communication lines.
!0
Data Selection Switch (COAX/RS485)
This switch selects either multiplex coaxial data or RS-
485 data from control data with the camera site.
485 data from control data with the camera site.
!1
Video Output Connector (VIDEO OUT)
Video signals from the camera are output from this con-
nector.
nector.
!2
Camera Input Connector (CAMERA IN)
This connector accepts the multiplexed video and con-
trol data signal from the specified camera such as WV-
CS854, WV-CS654 or WV-CS604 or a specified receiv-
er.
trol data signal from the specified camera such as WV-
CS854, WV-CS654 or WV-CS604 or a specified receiv-
er.
!3
AC Cord
!4
Power Switch (POWER ON/OFF)
This switch is used to turn the power of the System
Controller on and off.
Controller on and off.
Note:
Turning off this switch will not interrupt the power
supply. Disconnect the AC cord or turn off the cir-
cuit breaker when the controller is not used for a
long time.
cuit breaker when the controller is not used for a
long time.
!5
Signal Ground Terminal (SIGNAL GND)