Adtran 616 Manuel D’Utilisation

Page de 264
Section 5 DLP-6 
Total Access 600 Series System Manual
 200
© 2004 ADTRAN, Inc.
61200624L1-1B
1. Connect to the Total Access 6XX using either the 10/100BASET or CRAFT interface.
If you are not already connected to the unit’s 
CRAFT 
interface (either with a VT100 compatible 
Alternately, if the unit is part of a management cluster connected to the local network, you may use a 
PC connected to the network to Telnet into the unit. Use the procedures in DLP-3, Setting IP 
Parameters
, and DLP-5, Connecting to the Unit Using Telnet, to connect to the 
10/100BASET 
interface.
2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for more 
details). 
3. Go to the S
YSTEM
 C
ONFIG
/M
ANAGEMENT
/T
ELNET
 A
CCESS
 menu, select the U
SER
 L
IST
 menu, and press 
<Enter>.
4. Add a new user profile and password by selecting the first column (0) and pressing <I> (for insert).
5. Give the new user profile a name by selecting the N
AME
 field, pressing <Enter>, and typing the user 
defined name. All new Telnet entries have a I
NACTIVE
 as the N
AME
. Enter a specific username to use 
for Telnet login. Each Telnet entry in the list must have a unique assigned name because duplicate 
names are not allowed. Refer to System Config > Management > Telnet Access > User List on page 
53 fo
r more details.
6. Personalize the password for the appropriate level by selecting the P
ASSWORD
 field, pressing <Enter>
then typing the appropriate password. You will have to type the new password again to confirm it.
Passwords for the Total Access 6XX system are case sensitive. There is no default password for a new 
user (i.e., you can configure a user as blank with no password). The current password displays as a 
series of asterisks (********). 
7. Select the I
DLE
 T
IME
 field and press <Enter>. This field defines the amount of time in minutes the 
session may be idle before the user is logged off. The range is 1-255 and the default value is 10.
Perform the steps below in the order listed.
Password security levels only apply to users connecting to the Total Access 6XX system 
through Telnet access. All connections made through the 
CRAFT
 interface ALWAYS have 
maximum security rights.