Pelco C623M-C Manuel D’Utilisation

Page de 96
C623M-C (3/05)
23
RELAY OUTPUT INSTALLATION
The DX8000 has either 8 or 16 relay outputs, depending on your system’s configuration. Each output is programmed to function as either a 
normally open or normally closed circuit. A signal from a relay output will operate the device connected to the output.
 
To wire a relay output:
1. Insert the blue terminal blocks into the relay sockets on the back panel of the recorder.
2. Connect one wire from the device to one of the relay output terminals 1 through 16.
3. Connect a second wire from the relay device to a GND terminal.
4. Refer to the Operation/Programming manual for information on how to program relay outputs.
Figure 14.  Relay Terminal Installation
IMPORTANT:  The maximum relay power rating is 120 VAC, 0.5 A; 24 VDC, 1 A.
NOTE:  Relay outputs do not have to correspond numerically to alarm inputs. All sensor input and relay output actions can be linked 
through programming.
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16
OUT16
OUT15
OUT14
OUT13
OUT12
OUT11
OUT10
OUT9
OUT9
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
ALARM INPUTS
RELAY OUTPUTS
1
2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16
1
2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16
CRT
RELAY
OUTPUT 1
GND