The default level for the microphone is set to +3 dB. 
 
Audio inputs VCR Left/Right are set to a default level which is adhered to by most 
manufacturers of audio-visual equipment and is a level at which most audio-visual equipment 
(CD-players, VCRs or DVDs) will work. 
 
 
 
4.5.2    Outputs 
 
(not for TANDBERG 1500 MXP and 2000 MXP, software version F1)  
 
Audio Out 
 
Audio out is internally connected to the monitor loudspeakers. The signal is a mix of audio 
from far end and local end Audio in (VCR Left/Right). 
If an output is Off, no audio will be sent to that output. 
 
Level Settings 
 
Adjust the audio output level to the loudspeakers. 
The volume keys on the remote control also adjust the level of the audio output. 
 
4.5.3   Echo Control 
 
 
 
Microphone 
 
The microphone input has an acoustic echo canceller. In addition to echo cancellation, the 
system has built-in noise reduction (NR). NR reduces constant background noise (e.g. noise 
from air-conditioning systems, cooling fans etc.). In addition, a high pass filter (Humfilter) 
reduces very low frequency noise. 
 
On:    
Echo control is normally set to On to prevent the far end from hearing their 
own audio. Once selected, echo cancellation is active at all times. The echo 
canceller continuously adjusts itself to the audio characteristics of the room 
and compensates for any changes it detects in the audio environment. If the 
changes in the audio conditions are very significant the echo canceller may 
take a second or two to re-adjust. 
 
Off:  
Turns off the echo canceller.  
 
On+NR: 
 
 Activates both Echo Control and Noise Reduction. 
 
 
Note that it is your echo canceller that improves the audio quality experienced by the other 
site. When you hear an echo of your own audio it is most likely the far end
s echo 
canceller that is malfunctioning.