Figure 2.2. Rear Panel Connections 
 
 
 
 
 
 
 
 
 
 
 
Figure 2.3. Sensor input / Alarm output connections 
Dried Contact
1
2
3
4
OUT
(+)
(-)
(+)
(-)
+12VDC
ALARM
SENSOR
Sensor
Adapter
 
 
SENSOR INPUT: Connect two signal lines of sensor (infrared rays sensor, heat perception sensor, magnetic 
sensor) to the desired sensor number. (You can set the type-NC or NO- of sensor at “Setup” mode). 
ALARM OUTPUT: Use this at 30V/300mA or less operating voltage and current. When controlling lamp and 
AC operated equipment, control it using separate outside relay. During normal operation the control output 
contact is maintained at “Open” status, and during control output the output contact is changed to 
Close(short)” status. 
 
 
19
NOTICE 
SENSOR inputs need dried contact only. Do not input any electric signal.