4   INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT 
 
4.2 Installation 
4.2.1 Precautions for installation 
The precautions for installing the QD75MH are given below. Refer to this section as 
well as "4.1.3 Handling precautions" when carrying out the work. 
 
[1]   Precautions for SSCNET   cable wiring 
SSCNET   cable is made from optical fiber. If optical fiber is added a power 
such as a major shock, lateral pressure, haul, sudden bending or twist, its inside 
distorts or breaks, and optical transmission will not be available. Make sure to 
use optical fiber within the range of operating temperature described in this 
manual. The optical cable and code part melts down if being left near the fire or 
high temperature. Therefore, do not make it touched the part which becomes 
high temperature, such as radiator or regenerative brake option of servo 
amplifier, or servomotor. 
 
(1)   Minimum bend radius 
Make sure to lay SSCNET   cable with greater radius than the minimum 
bend radius. 
If the SSCNET   cable is less than the minimum bend radius, optical 
transmission is interrupted and it may cause malfunctions. 
 
SSCNET   cable 
Minimum bend radius [mm] ([inch]) 
MR-J3BUS   M 
25 
MR-J3BUS   M-A 
Reinforcement film cable : 50 (1.97) 
Code part : 25 (0.98) 
MR-J3BUS   M-B 
Reinforcement film cable : 50 (1.97) 
Code part : 30 (1.18) 
 
(2)   Tension 
If tension is added on SSCNET   cable, the increase of transmission loss 
occurs because of external force which concentrates on the fixing part of 
SSCNET   cable or the connecting part of SSCNET   connector. At 
worst, the breakage of SSCNET   cable or damage of SSCNET   
connector may occur. For SSCNET   cable laying, handle without putting 
forced tension. (For the tension strength, refer to section Appendix 3.1 
Connection of SSCNET   cables.) 
 
(3)   Lateral pressure 
If lateral pressure is added on optical cable, the SSCNET   cable itself 
distorts, internal optical fiber gets stressed, and then transmission loss will 
increase. At worst, the breakage of SSCNET   cable may occur. As the 
same condition also occurs at cable laying, do not tighten up SSCNET   
cable with a thing such as nylon band (TY-RAP).