Avaya 555-233-116 Manuel D’Utilisation

Page de 246
Data modules and asynchronous data units
555-233-116
60
Issue 4   October 2002 
* Circuits are not used for asynchronous operation. Outputs are clamped OFF and inputs are ignored.
Configuring the 7400A for data communications 
equipment (DCE) applications
If you are not going to use the 7400A data module in a modem pool, proceed as 
follows.
9  
— 
Reserved for Testing 
+12 volts
10 
— 
Reserved for Testing 
-12 volts
11
— Not 
used
— 
— 
12  
CI 
Data Signal Rate Select (DCE Source)
Output 
Input
13   
CI2
Data Signal Rate Select 2 (DCE Source)
— Input
14 
— Not 
used
— 
— 
15  
DB*
Transmitter Signal Element Timing (DCE 
Source)
Output Input
16
— Not 
used
— 
— 
17   
DD*
Receiver Signal Element Timing (DCE 
Source)
Output Input
18  
LL
Local Loopback
Input 
Output
19  
CH2
Data Signal Rate Select 2 (DTE Source)
— Output
20
CD (DTR)
Data Terminal Equipment Ready
Input 
Output
21 RL
Remove 
Loopback
Input 
Output
22 
CE (RI) 
Ring Indicator
Output 
Input
23    
CH
Data Signal Rate Select (DTE Source)
Input
Output
24  
DA*
Transmit Signal Element Timing (DTE 
Source)
Input
Output
25   
TM
Test  Mode 
Output
Input
Pin    
Name
Function
DCE
DTE
Continued on next page