Lucent Technologies 1079984G3 Manuel D’Utilisation

Page de 130
Issue 1
April 1997
67
Feature Descriptions
Administration
0
change system-parameters hospitality
On Page 1 of this form, enter an assignment in the 
Message Waiting 
Configuration
 field. If you do not have a PMS, or the message waiting 
notifications are not controlled by the PMS, put act-nopms in this field. If 
the message waiting notifications are controlled by the PMS, put 
act-pms in this field. The PMS vendor should be consulted concerning 
this setting.
change attendant 1
On Page 2 of this form, add the following feature buttons:
— mwn-act
— mwn-deact
change station XXXX (XXXX is the extension number of a backup voice termi-
nal)
Add the following feature buttons:
— mwn-act
— mwn-deact
change station XXXX (XXXX is the extension number of a visually impaired 
guest)
On Page 1 of this form, enter y in the 
Audible Message Waiting
 
field.
Required Hardware
0