Daewoo DTY-25G6/25G7 Manuel D’Utilisation

Page de 85
CP-520/520A/520F Service Manual 
 
DTV R&D Europe
 
38
available on one of the other CVBS inputs.In this condition the connections between the vision IF 
amplifier and the synchronisation circuit can be switched on and off by means of the VDX bit. 
The VDXEN bit must be set to “1” for this mode. 
 
The vertical synchronisation is realised by means of a divider circuit. 
 
5.2.7  Horizontal and vertical drive 
The horizontal drive is switched on and off via the soft start/stop procedure. The soft start 
function is realised by means of variation of the TON of the horizontal drive pulses. During the 
soft-stop period the horizontal output frequency is doubled resulting in a reduction of the EHT so 
that the picture tube capacitance can easily be discharged. In addition the horizontal drive circuit 
has a ‘low-power start-up’ function. 
 
The vertical ramp generator needs an external resistor and capacitor. For the vertical drive a 
differential output current is available. The outputs must be DC coupled to the vertical output 
stage. 
 
The IC has the following geometry control functions: 
n Vertical amplitude 
n Vertical slope 
n S-correction 
n Vertical shift 
n Vertical zoom 
n Vertical scroll 
n Vertical linearity correction. When required the linearity setting for the upper and lower part 
of the screen can have a different setting. 
n Horizontal shift 
n EW width 
n EW parabola width 
n EW upper and lower corner parabola correction 
n EW trapezium correction 
n Horizontal parallelogram and bow correction. 
 
When the East-West geometry function is not required (e.g. for 90 picture tubes) the EW output 
pin can be used for the connection of the AVL capacitor. This function is chosen by means of the 
AVLE bit. 
 
5.2.8  Chroma, luminance and feature processing 
 
Someversionscontaina4H/2H(2D)adaptivePAL/NTSC  comb filter. The comb filter is 
automatically activated when standard CVBS signals are received.A signal is considered as 
“standard signal” when a PAL or NTSC signal is identified and when the vertical divider is in the 
modes ‘standard narrow window’ or ‘standard TV norm’.For non-standard signals and for 
SECAM signals the comb filter is bypassed and the signal is filtered by means of bandpass and 
trap filters. 
 
The chroma band-pass and trap circuits (including the SECAM cloche filter) are realised by 
means of internal filters and are tuned to the right frequency by comparing the tuning frequency 
with the reference frequency of the colour decoder.