Daewoo DTY-2880/28W5 Manuel D’Utilisation

Page de 85
CP-520/520A/520F Service Manual 
 
DTV R&D Europe
 
44
PARAMETER 
A2/A2* 
A2+ (KOREA) 
Pilot frequency 
54.6875kHz = 3.5 x line freq. 
55.0699 kHz = 3.5 x line freq. 
Stereo identification frequency  117.5 Hz = line freq / 133 
149.9 Hz = line freq / 105 
Dual indetification frequency 
274.1 Hz = line freq / 57 
276.0 Hz = line freq / 57 
AM modulation depth 
50% 
50% 
 
2-CARRIERSYSTEMSWITHNICAM 
[Table] NICAM standards 
SC1 
MODULATION 
STANDARD  FREQUENCY 
(MHz) 
TYPE 
INDEX(%) 
NOM./MAX. 
DEVIATION 
(kHz) 
NAM./MAX. 
/OVER 
SC2 
(MHz) 
NICA
DE- 
EMPAHSIS 
ROLL-
OFF (%) 
NICAM 
CODING 
B/G 
5.5 
FM 
27/50/80 
5.85 
J17 
40 
Note1 
6.0 
FM 
27/50/80 
6.552 
J17 
100 
Note1 
D/K 
6.5 
FM 
27/50/80 
5.85 
J17 
40 
Note1 
6.5 
AM 
54/100 
5.85 
J17 
40 
Note1 
 
Note 1.  See ‘EBU specification’ or equivalent specification. 
 
5.4  FUNCTIONAL DESCRIPTION SOUND PROCESSOR 
5.4.1  The UOC III TV Sound Concept 
 
The UOCIII sound concept is implemented over the video processor and TCG-microcontroller. 
 
Only relevant blocks, functions and signal flows for sound are given. 
 
 
 
The tuner receives a RF signal and converts it to IF. Via appropriate SAW filters the SIF signal is 
delivered to the QSS stage of the video processor and if channels according to standard L/L’ are 
received also to the AM demodulator. The Quasi Split Sound demodulation generates the SSIF 
or intercarrier signal. By the SSIF switch it is possible to choose between the internally derived