Polycom DOC2702A Manuel D’Utilisation

Page de 1010
Polycom, Inc.
L-1
Appendix L
Homologation for Brazil
H.323 & SIP Protocol Flag Options 
Using a set of system flags, the user has the ability to select either Polycom proprietary or 
H.323/SIP standard protocol settings.
H.323 & SIP Flag Settings
Three flags are enabled on the MCU, allowing the user to define and select either standard or 
proprietary H.323 and SIP protocol settings. 
Flag name: SIP_TIMERS_SET_INDEX
Description: SIP Timer type timeout settings according to standard or proprietary protocol.
Flag section:   CS_MODULE_PARAMETERS 
Possible Values: either 0 or 1. 
0 - Polycom standard (flag default setting)
1 - SIP Standard recommendation. For homologation and certification testing, this flag must 
be set to 1.
For use as a reference, Table 1 lists the SIP timer types for each flag setting and their 
corresponding timeout values in milliseconds.
Table 1
 
SIP Timer Types & their Values
SIP TIMER Types
Value (in milliseconds)
POLYCOM (flag default)
Standard Recommended
T1  
50000
500
T2  
20000
4000
TimerB 
35000
32000
TimerC 
35000
60000
TimerD 
32000
32000
TimerF 
35000
32000
TimerH 
35000
32000
TimerI 
5000
5000
TimerJ 
32000
32000