Sterling 882.00249.00 Manuel D’Utilisation

Page de 70
 
 
2–Pump 12-Station Controllers 
Chapter 8: Service Only Information 
61 
HI VAC SENSOR DELAY?
       NO/YES 
 
 SELECT PUMP 1 OR 2
USE KEYPAD TO ENTER 
 
HIVAC DELAY:  3.000s
 SETTING FOR PUMP n 
 
Setting the Hi Vacuum Sensor Delay 
Hi vac sensor delay
 is the time that a high vacuum condition must exist before it is sensed by 
the controller. This delay eliminates the annoying Hi Vacuum errors which self-clear or are 
erroneous. This delay defaults to 3.0 seconds and should not be altered unless you are 
instructed to do so by the Service Department. 
 
 
 
 
 
 
 
 
At the above message prompt: 
1.  Press the YES key to enter the Hi Vacuum Sensor Delay Time menu. 
 
 
 
 
 
 
 
 
 
At the above message prompt: 
2.  Select the pump for altering vacuum sensor delay. 
The following screen displays: 
 
 
 
 
 
 
 
 
Using the keypad: 
3.  Enter the new time and press the ENTER key to save the new setting.