Chapter 3: Installation 
28 of 60 
 
If an Ethernet module was purchased with the system, the proper setting has to be changed to 
measure the extruder’s RPM with communications.  For details on changing the settings for 
measuring the extruder’s RPM, please refer to the Addendum 7-4.   
The controller will be factory set to use the Ethernet module if it has been supplied. 
Final Connections 
Connect the rate monitor to the appropriate power source. 
Connect the compressed air piping, ensuring that a 5-micron air filter is installed, along with 
the proper water trap. Verify that 60-psi of clean, dry compressed air is supplied to the GH 
Hopper. 
After powering up the rate monitor, the following screen will be shown: 
 
 
Figure 13: Display Startup Screen 
 
 
 
This screen displays the software version of both the PLC and the Panel View.  The 
Controller will stay on this screen for about 10 seconds or you can touch the ACS icon to 
quickly skip to the Recipe Screen (Next Screen in sequence).  The software versions are also 
available on the Panel View Configuration Screen. 
Figure 14: GH-M Display Main (Recipe) Screen 
 
 
 
To access the Setup Menu to change the controller features, refer to the following pages of 
this manual. 
Note:   It may take 45-50 seconds for the screen to appear. 
Touch here to skip 
quickly to the Recipe 
Screen (Next Screen 
in sequence).