Avaya S8100 Manuel D’Utilisation
1
Install and cable a G600 cabinet
Install emergency-transfer panel and associated telephones
S8100 Installation and Upgrades
129
November 2003
3
Locate the circuit start selection switches (the 1
st
10 2-position switches on the left side of the
808A. See
on page 128.) These switches set each of
the 5 incoming trunk lines to either loop start or ground start. Two switches are used for each of
the 5 circuits; switches 1 and 2 are used for circuit 1, switches 3 and 4 are used for circuit 2, and
so forth. See
the 5 circuits; switches 1 and 2 are used for circuit 1, switches 3 and 4 are used for circuit 2, and
so forth. See
4
Connect a 25-pair cable between the male RJ21 25-pair connector on the 808A and the yellow
field on the MDF.
field on the MDF.
on page 130 shows
the pinouts.
5
Make cross-connections for each emergency trunk/emergency station pair. See
on page 132 and
6
On the trunk identification label at the bottom of the panel, record the trunk line, extension, and
location for each circuit.
location for each circuit.
7
To each voice terminal designated as an emergency terminal, attach a label identifying it as such.
The labels are provided with the unit.
The labels are provided with the unit.
8
Check the system for normal operation as follows:
a
Place the test switch (switch 12) in NORMAL OPERATION.
b
Ensure the power supply is providing -48 VDC at 80 mA maximum. The power LED
should be ON.
should be ON.
c
Check wiring connections.
d
Verify that there is dial tone on every emergency transfer set.
Table 20: Trunk/test switches
Switch
number
number
Circuit
number
number
1
1
2
1
3
2
4
2
5
3
6
3
7
4
8
4
9
5
10
5
11
Not used
12
Test switch