KVH Industries FB500 Manuel D’Utilisation

Page de 212
v
Grounding, cables and connections
To minimize shock hazard, the equipment chassis and cabinet must be 
connected to an electrical ground. Both terminal and antenna must be 
grounded to the vehicle. For further grounding information refer to the 
Installation manual.
Do not extend the cables beyond the lengths specified for the equipment. 
The cable between the terminal and antenna can be extended if it complies 
with the specified data concerning cable losses etc.
All cables for the TracPhone system are shielded and should not be affected 
by magnetic fields. However, try to avoid running cables parallel to AC 
wiring as it might cause malfunction of the equipment.
Power supply
The voltage range is 10.5 - 32 V DC; 14 A - 5.5 A. It is recommended that the 
voltage is provided by the 24 V DC bus on the ship. Be aware of high start-up 
peak current: 20 A@24 V, 5 ms.
If a 24 V DC power bus is not available, an external 115/230 VAC to 24 V DC 
power supply can be used.
Do not operate in an explosive atmosphere
Do not operate the equipment in the presence of flammable gases or fumes. 
Operation of any electrical equipment in such an environment constitutes a 
definite safety hazard.
Keep away from live circuits
Operating personnel must not remove equipment covers. Component 
replacement and internal adjustment must be made by qualified 
maintenance personnel. Do not replace components with the power cable 
connected. Under certain conditions, dangerous voltages may exist even 
with the power cable removed. To avoid injuries, always disconnect power 
and discharge circuits before touching them.
Failure to comply with the rules above will void the warranty!
BGAN-X_UM.book  Page v  Wednesday, April 30, 2008  12:48 PM