Description of the motor 
 
2.3 Selection and ordering data 
Order desig. /  
Size 
Rated torque
1)
 
M
N
 
in Nm 
Max. torque 
M
MAX 
 
in Nm 
Rated 
current
1) 
I
 
in A 
Max. current 
I
MAX
 
in A 
Max. speed at  
rated torque
2) 
n
MAX,MN 
 
in rpm 
Max. speed at 
max. torque
2)
 
 n
MAX,MMAX 
 
in rpm 
1FW6230-xxB10-2Jxx 
1630 
2630 
23 
45 
46 
21 
1FW6230-xxB10-5Gxx 
1520 
2630 
48 
100 
130 
74 
1FW6230-xxB10-8Fxx 
1450 
2630 
62 
130 
190 
110 
1FW6230-xxB10-2Pxx 
1320 
2630 
80 
190 
290 
160 
1FW6230-xxB15-4Cxx 
2440 
3950 
32 
63 
43 
19 
1FW6230-xxB15-5Gxx 
2380 
3950 
49 
100 
80 
44 
1FW6230-xxB15-8Fxx 
2310 
3950 
66 
130 
120 
67 
1FW6230-xxB15-2Pxx 
2190 
3950 
90 
190 
180 
100 
1FW6230-xxB15-0Wxx 
2020 
3950 
110 
270 
270 
150 
1FW6230-xxB20-5Gxx 
3230 
5260 
51 
100 
56 
29 
1FW6230-xxB20-8Fxx 
3160 
5260 
69 
130 
84 
47 
1FW6230-xxB20-2Pxx 
3050 
5260 
94 
190 
130 
74 
1FW6230-xxB20-0Wxx 
2890 
5260 
120 
270 
190 
110 
1FW6290-xxB07-5Gxx 
2060 
4000 
52 
110 
110 
59 
1FW6290-xxB07-0Lxx 
1910 
4000 
86 
210 
210 
110 
1FW6290-xxB07-2Pxx 
1810 
4000 
100 
270 
270 
150 
1FW6290-xxB11-7Axx 
3320 
6280 
59 
130 
73 
40 
1FW6290-xxB11-0Lxx 
3200 
6280 
91 
210 
130 
71 
1FW6290-xxB11-2Pxx 
3100 
6280 
110 
270 
170 
93 
1FW6290-xxB15-7Axx 
4590 
8570 
61 
130 
53 
28 
1FW6290-xxB15-0Lxx 
4480 
8570 
94 
210 
89 
50 
1FW6290-xxB15-2Pxx 
4390 
8570 
110 
270 
120 
67 
1FW6290-xxB20-0Lxx 
5760 
10900 
95 
210 
68 
38 
1FW6290-xxB20-2Pxx 
5670 
10900 
120 
270 
91 
51 
1)
 Water cooling with 35 °C intake temperature; 
2)
 Speed and current values at converter DC link voltage U
ZK
 = 600 V 
(regulated)/converter output voltage (rms value) U
amax
 = 425 V (regulated) 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7 
31