Emerson 951C Manuel D’Utilisation

Page de 64
Instruction Manual 
748214-V 
June 2009 
Rosemount Analytical Inc.    A Division of Emerson Process Management                                                                
                Contents     iii 
Model 951C 
4-1 
Nitric Oxide Determination by Chemiluminescence Method .................................................4-1 
4-2 
Analyzer Flow System ...........................................................................................................4-1 
a.  Flow of Sample, Standard Gas or Zero Gas to Reaction Chamber ...............................4-1 
b.  Ozone Generation...........................................................................................................4-1 
4-3 
Signal Conditioning And Display ...........................................................................................4-2 
a.  Circuit Functions .............................................................................................................4-2 
4-4 
Analyzer Thermal System .....................................................................................................4-3 
5.0 
ROUTINE SERVICING..........................................................................................................5-1 
5-1 
System Checks and Adjustments..........................................................................................5-1 
a.  Display Fullscale Span Adjustment.................................................................................5-1 
b.  Overall Sensitivity............................................................................................................5-1 
c.  Ozone Output..................................................................................................................5-2 
d.  Background Current ........................................................................................................5-2 
5-2 
Servicing Flow System ..........................................................................................................5-2 
a.  Cleaning Sample Capillary..............................................................................................5-3 
b.  Ozone Restrictor Fitting ..................................................................................................5-3 
5-3 
Photomultiplier Tube/Reaction Chamber ..............................................................................5-4 
a.  Removal ..........................................................................................................................5-4 
b.  Cleaning Reaction Chamber...........................................................................................5-4 
c.  Photomultiplier Tube and Housing..................................................................................5-5 
d.  Replacement of Photomultiplier Tube.............................................................................5-6 
5-4 
Ozone Generation System ....................................................................................................5-6 
a.  Lamp/Housing Removal..................................................................................................5-6 
b.  UV Lamp Replacement ...................................................................................................5-7 
c.  Power Supply Removal...................................................................................................5-7 
5-5 
Converter Assembly ..............................................................................................................5-7 
5-6 
Servicing Electronic Circuitry.................................................................................................5-8 
6.0 
REPLACEMENT PARTS ......................................................................................................6-1 
6-1 
Matrix .....................................................................................................................................6-1 
6-2 
Circuit Board Replacement Policy .........................................................................................6-3 
6-3 
Replacement Parts ................................................................................................................6-3 
a.  Common Parts ................................................................................................................6-3 
b.  Photomultiplier Assembly 654062...................................................................................6-4 
c.  Converter Assembly 654070...........................................................................................6-5 
d.  Temperature Control Assembly 654068 .........................................................................6-6 
7.0 
RETURN OF MATERIAL ......................................................................................................7-2 
7-1 
return of material ...................................................................................................................7-2 
7-2 
customer service ...................................................................................................................7-2 
7-3 
Training..................................................................................................................................7-2 
8.0 
INDEX....................................................................................................................................8-1