Manuel D’UtilisationTable des matièresINSTALLATION1CHAPTER ONE INTRODUCTION3TABLE OF CONTENTS51 PURPOSE72 ORGANIZATION73 REFERENCE DOCUMENTATION74 SYSTEM MNEMONICS/TERMS7CHAPTER TWO SITE REQUIREMENTS13TABLE OF CONTENTS151 GENERAL172 INPUT POWER REQUIREMENTS173 SITE CONSIDERATIONS174 GROUNDING REQUIREMENTS18CHAPTER THREE SYSTEM CONFIGURATION211 INTRODUCTION232 SYSTEM CAPACITY233 STATION CONSIDERATIONS274 TELEPHONE UPGRADES315 CONFIGURATION EXAMPLES316 CONFIGURATION WORKSHEETS32CHAPTER FOUR DK8 KSU AND PCB INSTALLATION43TABLE OF CONTENTS45PART I. KSU INSTALLATION471 GENERAL472 KEY SERVICE UNIT MOUNTING473 POWER SUPPLY REMOVAL AND REPLACEMENT514 DK8 POWER FAILURE EMERGENCY TRANSFER OPTION51PART II. PRINTED CIRCUIT BOARD INSTALLATION555 GENERAL556 PCB INSTALLATION CONSIDERATIONS557 CO LINE/DIGITAL TELEPHONE INTERFACE UNIT (QCDU)558 STANDARD TELEPHONE INTERFACE UNIT (QSTU)599 DTMF RECEIVEWABR TONE DETECTOR UNIT (QRCU)5910 CONFERENCE CIRCUITS (QCNU)6111 OPTION INTERFACE UNIT (QSMU)6212 BUILT-IN CO LINE, DIGITAL TELE- PHONE, AND OTHER CIRCUITS63CHAPTER FIVE DK16 KSU AND PCB INSTALLATION65TABLE OF CONTENTS67PART I. KSU INSTALLATION711 GENERAL712 KEY SERVICE UNIT MOUNTING713 POWER SUPPLY REMOVAL AND REPLACEMENT81PART II. DK16 PRINTED CIRCUIT BOARD INSTALLATION834 GENERAL835 DK16 PCB INSTALLATION CONSIDERATIONS836 BASE UNIT STANDARD TELEPHONE INTERFACE UNIT (KSTU)847 DIGITAL TELEPHONE liTERFACE UNIT (PDKU)858 ELECTRONIC TELEPHONE INTERFACE UNIT (PEKU)879 STANDARD TELEPHONE INTERFACE UNIT (PSTU)9010 STANDARD/ELECTRONIC TELE- PHONE INTERFACE UNIT (PESU)9211 CO LINE UNIT (PCOU)9512 OPTION INTERFACE UNIT (PIOU AND PIOUS)9813 CO LINE/DIGITAL TELEPHONE INTERFACE UNIT (KCDU)10114 DTMF RECEIVEWABR TONE DETECTOR UNIT (K4RCU)10315 BUILT-IN CO LINE AND DIGITAL TELEPHONE CIRCUITS10416 KCOU REMOVAL AND REPLACEMENT10517 DK16 POWER FAILURE EMERGENCY TRANSFER OPTION106CHAPTER SIX STATION APPARATUS INSTALLATION .107TABLEOFCONTENTS1091 OVERVIEW1112 TELEPHONE INSTALLATION1113 DIGITAL TELEPHONE UPGRADES1144 ELECTRONIC TELEPHONE UPGRADE OPTIONS (DK16 Only)1215 DIRECT STATION SELECTION CONSOLE/SYSTEM CONNECTION (DKI 6 Only)1246 DOOR PHONE/LOCK CONTROL UNIT AND DOOR PHONE INSTALLATION1257 ADD-ON MODULE INSTALLATION127CHAPTER SEVEN PERIPHERAL INSTALLATION1291 GENERAL1332 MUSIC-ON-HOLD/BACKGROUND MUSIC OPTIONS1333 RELAY CONTROL OPTIONS1364 EXTERNAL SPEAKER UNIT (HESB) OPTIONS1445 EXTERNAL PAGE OPTIONS1516 DK8 AND DK16 STATION MESSAGE DETAIL RECORDING (SMDR) PRINTER/ CALL ACCOUNTING DEVICE OPTIONS1557 VOICE MAIL OPTIONS1608 DK16 ALARM SENSOR INSTALLATION1649 DK16 NIGHT RINGING OVER EXTERNAL ZONE PAGE16510 DATA INTERFACE UNIT INSTALLATION166** DK8 AND DK16 PDIU-DI TO IBM AT-TYPE COMPUTER, RS-232 CONNECTOR/CABLE CONNECTIONS **17411 DK16 TWO-CO LINE EXTERNAL AMPLIFIED CONFERENCE188CHAPTER EIGHT WIRING DIAGRAMS191TABLEOFCONTENTS1931 GENERAL1952 WIRING DIAGRAMS195PROGRAMMING PROCEDURES227CHAPTER ONE INTRODUCTION227TABLE OFCONTENTS2291 PURPOSE2312 ORGANIZATION2313 GENERAL PROGRAMMING INSTRUCTIONS2314 AFTER INITIALIZATION2385 TELEPHONE BUTTON LABELS238INITIALIZATION PROGRAM 92 INITIALIZING SPEED DIAL NUMBERS, VM ID CODES, CHARACTER MESSAGE MEMORY, TIMED REMINDERS, DIGITAL TELEPHONE VOLUME, AND CALL FORWARD BACKUP MEMORY239TABLE 1 -E PROGRAM 03 SLOT ASSIGNMENTS (DK16 ONLY)241PROGRAM 00 SOFTWARECHECKANDREMOTEMAINTENANCESECURITYCODEASSIGNMENTS242PROGRAM 04 PORT AND STATION NUMBER ASSIGNMENT244SETTINGSYSTEM DATE245SETTINGSYSTEMTIME245SETTING SYSTEM DAYOFWEEK245TELEPHONEBUTTON LABELS246CHAPTER TWO INSTRUCTIONS/RECORD SHEETS247TABLEOFCONTENTS2491 GENERAL2512 TOLL RESTRICTION2723 TOLL RESTRICTION OVERVIEW2724 COMPLETING THE TOLL RESTRICTION SYSTEM RECORD2735 LEAST COST ROUTING (LCR)2786 LEAST COST ROUTING (LCR) OVERVIEW2787 COMPLETING THE LEAST COST (LCR) ROUTING SYSTEM RECORD280SYSTEM RECORD SHEETS285PROGRAM NUMBER INDEX287PROGRAMS 00 - 97 IN NUMERICAL ORDER WITH SECTIONS CROSS-REFERENCED289PROGRAM 92 INITIALIZING SPEED DIAL NUMBERS, VM IO CODES CHARACTER MESSAGE MEMORY, TIMED REMINDERS, DIGITAL TELEPHONE VOLUME, AND CALL FORWARD BACKUP RAM293PROGRAM 03 OK16 FLEXIBLE PCB SLOT ASSIGNMENTS294PROGRAM 00 SOFTWARE CHECK/REMOTE MAINTENANCE SECURITY CODE ASSIGNMENTS295PROGRAM 01 LOGICALSTATION PORTDISPLAY296PROGRAM 02 PHYSICAL STATION PORT DISPLAY297PROGRAM 04 LOGICAL PORT INTERCOM NUMBER ASSIGNMENT298PROGRAM 05 FLEXIBLEACCESSCODENUMBERING299PROGRAM 10-1 SYSTEMASSIGNMENTS,PARTlOF3300PROGRAM 10-2 SYSTEM ASSIGNMENTS, PART 2 OF 3301PROGRAM 10-3 SYSTEM ASSIGNMENTS, PART 3 OF 3302PROGRAM 12 SYSTEM ASSIGNMENTS - BASIC TIMING303PROGRAM 13 DEFINING THE MESSAGE CENTER304PROGRAM 15 ASSIGNING DP/DTMF, TENANT SERVICE TO INDIVIDUAL CO LINES305PROGRAM 16 ASSIGNING CO LlNEGROUPS(DIAL9 OR81-88)306PROGRAM 19 DK16 ALTERNATE BACKGROUND MUSIC (BGM) SOURCE SLOT ASSIGNMENT307PROGRAM 20 DATA INTERFACE UNIT (DIU) PORT CONFIGURATION308PROGRAM 21 MODEM POOL PORT ASSIGNMENTS309PROGRAM 22 DATA INTERFACE UNIT (DIU) STATION HUNTING (DATA CALLS ONLY)310PROGRAM 28 DK16 DSS CONSOLE/ATTENDANT TELEPHONE ASSIGNMENTS311PROGRAM 29-1, 29-27 DK16 DSS CONSOLE (DDSS AND HDSS) BUTTON ASSIGNMENTS CONSOLE 0312PROGRAM 29 DK16 INITIALIZED DSS CONSOLE (DDSS AND HDSS) BUTTON ASSIGNMENTS313PROGRAM 30 STATIONCLASSOFSERVICE314PROGRAM 31 STATION CLASSOFSERVICE315PROGRAM 32 AUTOMATIC PREFERENCE316PROGRAM 33 STATION HUNTlNG(VOICE CALLS ONLY)317PROGRAM 34 HOLD/PARK RECALL TIMING318PROGRAM35 STATIONCLASSOFSERVICE319PROGRAM 36 FIXED CALL FORWARD320PROGRAM 37 RING TRANSFER (CAMP-ON) RECALL TIME321PROGRAM 38 DIGITAL AND ELECTRONIC TELEPHONE BUTTONSTRIP TYPE322PROGRAM 39 FLEXIBLE BUTTON ASSIGNMENT REFERENCE GUIDE324PROGRAM 90 INITIALIZING PROGRAMS 00 - 97326PROGRAM 39 FLEXIBLE BUTTON ASSIGNMENT FOR PORTS TO327PROGRAM 40 STATIONCO LINEACCESS328PROGRAM 41 STATION OUTGOING CALL RESTRICTION329PROGRAM 42-O CO LINE TO PBX/CENTREX CONNECTION330PROGRAM 42-1-8 PBX/CENTREXACCESSCODES331PROGRAM 43 0+ CREDITCARD DIALING OPTION332PROGRAM 44A EMERGENCYBYPASSOFFORCED/VERIFIEDACCOUNTCODES333PROGRAM 60 SMDR OUTPUT/ACCOUNT CODE DIGIT LENGTH335PROGRAM 69 VERIFIED ACCOUNT CODES (V.A.C.s)336PROGRAM 70 VERlFlEDACCOUNTCODETOLLRESTRlCTlONASSlGNMENTS337PROGRAM 77-1 PERIPHERAL OPTIONS (DOOR PHONES/IMDU/BASE UNIT RELAY/PIOU/PIOUS)338PROGRAM 77-2 DOOR PHONE BUSY SIGNAL/DOOR LOCK ASIGNMENTS339PROGRAM 78 CO LINE SPECIAL RINGING ASSIGNMENTS DISA/IMDU/NIGHT RINGING OVER EXTERNAL PAGE340PROGRAM 79 DOOR PHONE RINGING341PROGRAM 80 DIGITALAND ELECTRONICTELEPHONE RlNGlNGTONES(C0 LINECALLS)342PROGRAM 8(X) (I- 9) CO LINE/STATION RINGING ASSIGNMENTS343PROGRAM 93 CO LINE IDENTIFICATION345PROGRAM 97 PRINTING PROGRAM DATA THROUGH SMDR347SETTING THE DATE, TIME AND DAY348TOLL RESTRICTION SYSTEM RECORD SECTION Programs 44B - 48349PROGRAM 44B TOLLRESTRICTION/TRAVELINGCLASSOVERRlDECODES350PROGRAM 45-1 LCR/TOLLRESTRICTION DIALPLAN351PROGRAM 45-2 TOLL RESTRICTION DISABLE352PROGRAM 45-3-6 EQUALACCESS/SPECIALCOMMONCARRlER(SPCC)NUMBERSANDAUTHORlZATlONCODEDlGlT LENGTH353PROGRAM 45-8-9 TOLLRESTRICTION OVERRIDECODE354PROGRAM 46-2-4 TOLLRESTRlCTlONALLOWED/DENIEDAREACODESASSlGNED BYCLASS355PROGRAM 46-6-8 TOLLRESTRlCTlONALLOWEO/DENIEDOFFlCECODESASSlGNED BYCLASS356PROGRAM 46-10, -20, -30, -40 TOLLRESTRICTION CLASS1 PARAMETERS357PROGRAM 47 TOLL RESTRICTION EXCEPTION OFFICE CODES ASSIGNED BY AREA CODES (TABLES 1 AND 2)358PROGRAM 48 STATION TOLL RESTRICTION CLASSIFICATION359PROGRAMMING PROCEDURES LEAST COST ROUTING SYSTEM RECORD SECTION Programs 50 - 56361LCR CO LINE PROGRAMING363PROGRAM 50-1 LCRPARAMETERS363PROGRAM 50-2 LCRHOMEAREACODE364PROGRAM 50-31-35 LCRSPECIALCODES364PROGRAM 50-4 LCR LONG DISTANCE INFORMATION (LOI) PLAN NUMBER365PROGRAM 50-5 LCR LOCAL CALL ROUTE PLAN NUMBER365PROGRAM 50-6 LCR DIAL ZERO TIMEOUT365PROGRAM 51 LCRAREACODES366PROGRAM 52 LCROFFlCECODEEXCEPTlONSFORSPEClFlEDAREACODE368PROGRAM 53 LCR SCHEDULE ASSIGNMENTS FOR LCR PLAN NO. 1 AND 2370PROGRAM 54 LCR ROUTE DEFINITION TABLES(l -4)374PROGRAM 55 LCR MODIFIED DIGITS TABLES376PROGRAM 56 LCRSTATIONGROUPASSIGNMENT377USER GUIDES381LCD Telephone User Guide381Digital Telephone User Guide405Single Line Telephone User Guide451Add-On Module and DSS User Guide465System Administrator's Guide475FAULT FINDING PROCEDURES489REMOTE ADMINISTRATION AND MAINTENANCE507Taille: 38 MoPages: 584Language: EnglishOuvrir le manuel