14 
MINIMUM RANGE FIELD 
MAXIMUM RANGE FIELD 
MIDI PORT/CHANNEL FIELD 
 
 AFTERTOUCH PARAMETERS 
 
For some applications, you might wish to use the faders or knobs as Aftertouch controllers.  In this scenario, 
the knob or fader will transmit Aftertouch information which could be used to control, say, vibrato or tremolo.  
The following list of parameters can be accessed if “Aftertouch” is selected as the event type for the knob or 
fader. 
 
 MIDI CHANNEL FIELD 
 
This field sets the MIDI Port and Channel which the knob or fader will use 
to transmit messages.  You can assign knobs and faders to one of two 
MIDI Ports, A or B, and to one of 16 MIDI Channels on each port (i.e. 
A14).  You can also assign a knob or fader to use the MIDI Common 
Channel. 
1.
  Press [<] to select MIDI Port/Channel field. 
2.
  While in MIDI Port/Channel field, use [VALUE] dial to select desired 
MIDI Port and Channel. 
3.
  Press [>] to select the next field. 
Note:  When not used via USB, only knobs and faders assigned to port 
A will be transmitted via the 5-pin MIDI port on the back of the MPD26. 
 
 
 MINIMUM RANGE FIELD 
 
This field is used to specify the minimum value that the knob or fader can 
transmit. 
1.
  Use [<] or [>] buttons to select Minimum Range field. 
2.
  While in Minimum Range field, use [VALUE] dial to select desired 
minimum aftertouch value. 
3.
  Use the [>] button to select the next field. 
 
 
 
 MAXIMUM RANGE FIELD 
 
This field is used to specify the maximum value that the knob or fader can 
transmit. 
1.
  Use the [<] or [>] buttons to select Maximum Range field. 
2.
  While in Maximum Range field, use [VALUE] dial to select desired 
maximum value. 
 
 
 
 
 
 
 
 
 
 
 
When finished editing, press [ENTER] to save or [<] to cancel the changes.