Roland GR-33 Manuale Utente

Pagina di 128
17
Chapter 1 Producing Sounds
Chap.
1
Overall Settings for the GR-33 (SYSTEM)
Adjusting the Brightness of the 
Display (LCD Contrast)
Adjusting the Brightness of the Display
1. Press [SYSTEM] to enter System mode.
2. Press [PARAMETER] to select “LCD CONTRAST.”
fig.1-06
3. Turn [VALUE] to adjust the contrast.
4. When you have finished adjusting the display, press 
[PLAY] to return to Play mode.
Setting Input Sensitivity (PICKUP 
SENS)
With the power turned on, adjust the input sensitivity of 
each string according to how the GK-2A is mounted and to 
match your own picking strength. Since these settings are 
stored automatically—and will not be lost even if the power 
is turned off—it is not necessary to reset the sensitivity each 
time you play.
Procedure for Setting Input Sensitivity
1. Press [SYSTEM] to enter System mode.
2. Press [PARAMETER] to select “PICKUP SENS.”
Sensitivity-setting is activated, and the following 
appears in the display window:
fig.1-07
3. When String 6 of the guitar is played, the string 
number in the display automatically switches to “6.”
The level meter shown in the display will light from the 
left, showing how strongly the string is played. The 
current input-sensitivity setting for the string will also be 
displayed next to the string number.
4. Use [VALUE] to adjust the sensitivity so that the square 
indicator lights when you play most strongly in actual 
performance.
fig.1-21
If the indicator furthest to the left is lit, the level is set too 
high, so turn [VALUE] to lower the sensitivity.
* If the sensitivity is set too high, there may be dropouts in the 
sound, or the response to dynamic changes in your playing 
may be reduced. Setting sensitivity too low may also result in 
problems, so make this adjustment carefully.
5. Adjust Strings 5 to 1 using the same technique.
6. When you have finished, press [PLAY] to return to Play 
mode.
In any of the following situations, please be 
sure to readjust the sensitivity settings!
• When using a guitar for which you have not yet made 
sensitivity adjustments
• When you change the mounting of the GK-2A to 
accommodate a change in the guitar, such as when string 
height has been readjusted
• When you replace a string with one of a different gauge
In some rare cases, the sensitivity meter may show too high a 
reading even with sensitivity at its lowest setting. If this does 
occur, widen the space slightly between the GK-2A’s 
separate pickups and the strings.
Using Multiple Guitars (GUITAR SELECT)
You can store four separate string-sensitivity setups that can 
be called up to match any of four guitars you are currently 
using.
Calling Up the Different Sensitivity Settings
1. Press [SYSTEM] to enter System mode.
2. Press [PARAMETER] to select “GUITAR SELECT.”
fig.1-08
String Number
Input Sensitivity
Level Meter
Sensitivity: low
Sensitivity: hi