Lg Electronics 120S Manuale Utente

Pagina di 306
Chapter 11  Troubleshooting 
11-12 
 
 
11.5 Error code list 
 
Error 
Code 
Message 
CPU state 
Message 
Cause 
Corrective Actions 
0001h 
Internal system 
error 
Stop System 
Error 
Fault of some area of operating ROM, 
or H/W defect 
Contact the service center.
0002h 
OS ROM error 
Stop 
OS ROM Error 
Internal system ROM is defected 
Contact the service center.
0003h 
OS RAM error 
Stop 
OS RAM Error 
Internal system RAM is defected 
Contact the service center.
0004h 
Data RAM error 
Stop 
DATA RAM Error 
Data RAM is defected 
Contact the service center.
0005h 
Program RAM 
error 
Stop 
PGM RAM Error 
Program RAM is defected 
Contact the service center.
0006h 
Gate array error 
Stop 
G/A Error 
Defect of dedicated LSI for sequence 
instruction processing 
Contact the service center.
0007h 
Sub rack power 
down error 
Stop 
Sub Power Error 
Extension Rack Power down or Error 
Check the power of the 
extension rack 
0008h 
OS WDT error 
Stop 
OS WDT Error 
CPU OS watch dog error 
Turn the power off and 
restart the system.   
Contact the service center.
0009h 
Common RAM 
error 
Stop 
Common RAM Error 
Common RAM interface error 
Contact the service center.
000Ah  Fuse break error 
Continue 
(stop) 
I/O Fuse Error 
Break of fuse used in output units or 
Mixed I/O 
Check the fuse LED of the 
unit. Turn the power off 
and replace the fuse. 
000Bh 
Instruction code 
error 
Stop 
OP Code Error 
Instructions unreadable by the CPU 
are included. (during execution) 
Contact the service center.
000Ch 
Flash memory 
error(during 
execution) 
Stop 
User Memory Error 
Read to/Write from the inserted Flash 
memory is not performed. 
Check and replace the 
flash memory. 
0010h 
I/O slot error 
Stop 
I/O Slot Error 
during operation, or connection fault 
defect 
mount the unit firmly, and 
restart the system. 
extension cable. 
0011h 
Maximum I/O 
error 
Stop 
MAX I/O Error 
Points of mounted I/O units overrun 
the maximum I/O points. (FMM 
mounting number over error, 
MINI_MAP over…) 
Replace the I/O unit. 
0012h 
Special card 
interface error 
Stop 
Special I/F Error 
Special Card Interface error 
Contact the service center.
0013h 
FMM 0 I/F error 
Stop 
FMM 0 I/F Error 
FMM 0 I/F Error 
Contact the service center.
0014h 
FMM 1 I/F error 
Stop 
FMM 1 I/F Error 
FMM 1 I/F Error 
Contact the service center.
0015h 
FMM 2 I/F error 
Stop 
FMM 2 I/F Error 
FMM 2 I/F Error 
Contact the service center.
0016h 
FMM 3 I/F error 
Stop 
FMM 3 I/F Error 
FMM 3 I/F Error 
Contact the service center.
0020h 
Parameter Error 
Stop 
Parameter Error 
A written parameter has changed, or 
checksum error 
Correct the content of the 
parameter.  
0021h 
I/O Parameter 
Error 
Stop  
(continue) 
I/O Parameter Error 
When the power is applied or RUN 
starts, I/O unit reservation information 
differs from the types of real loaded 
I/O units.   
Correct the content of the 
parameter, or reallocate or 
replace the I/O unit.   
0022h 
Maximum I/O 
Over 
Stop 
I/O PARA Error 
The point of the reserved I/O 
information or real loaded I/O units 
overruns the maximum I/O point.     
Correct the content of the 
parameter. 
0023h 
FMM 0 Parameter 
Error 
Stop 
FMM 0 PARA Error 
FMM 0 Parameter Error 
Correct the parameter.   
0024h 
FMM 1 Parameter 
Error 
Stop 
FMM 1 PARA Error 
FMM 1 Parameter Error 
Correct the parameter. 
0025h 
FMM 2 Parameter 
Error 
Stop 
FMM 2 PARA Error 
FMM 2 Parameter Error 
Correct the parameter.