Invacare IRC5PW Manuale Utente

Pagina di 91
Control Panel and P.C. Board
10 Liter Models
Item
Number
Part Number
Description
Note
Quantity Per
Package Assembly
1132056
Control Panel Assembly - 10LX
1
1
1
1130682
Control Panel Assembly - 10LXO2
1
1
1
2000507
Palnut (9/16-18)
1
3
2
1056554
Circuit Breaker (8 AMP)
1
1
3
1098707
Hour Meter Assembly with Clip
1
1
4
2001134
Switch, On/Off
1
1
5
1130062
Label, Control Panel - 10LX
1
1
6
1125073
Label, Control Panel - 10LXO2
1
1
6
1128739-NLA
NLA - Flowmeter without Palnuts
1
1
7
D,E
1135961
Flowmeter Assembly
1
1
7
D
2000473
Connector, Barbed (1/4")
1
1
8
1128738
Label, Logo
1
1
9
1102696
Screw, Phillips Pan Head SEMS (#8-32 x 3/8")
1
2
10
1085200
Transformer Assembly
1
1
11
1110779
Tubing Assembly, Check Valve Discharge
1
1
12
A,H
1108815
Tubing, Silicon (1/4 x 16-1/4")
1
1
13
H
1108809
Tubing, PVC (1/4 x 12-3/4")
1
1
14
1128737
PCB Control Assembly - 10LX
1
1
15
1128742
PCB Control Assembly - 10LXO2
1
1
15
1128742E
WARR RPLMT - PCB Control Assembly - 10LXO2
1
1
15
1108737
Harness, Wire, 10 Pin
1
1
16
1076275
Tubing, Tygon (1/8 x 18")
1
1
17
2001902-NLA
NLA - Screw, Phillips Pan Head (#4-40 x 1/4")
1
2
18
1128404
Screw, Phillips Hex Washer Head (#8-32 x 3/8")
1
2
19
2003065-NLA
NLA - Screw, Phillips Hex Washer Head (#8-32 x
3/8")
1
2
19
1128379
Package, Knob, Flowmeter, Silver w/ Black Swish
10
1
20
C
1128380
Package, Knob, Flowmeter, Black w/ Silver Swish
10
1
20
B
2001764
Jumper Wire Assembly
1
1
21
2001682
Tie Wrap (8" L)  
1
2
22
F,G
1110473
Tubing, PVC (1/4 x 1-3/4")
1
2
23
F,G
2000460
Valve, Check
1
1
24
F,G
P0750X030
Filter, HEPA Outlet
1
1
25
F,G
1143144
Tubing, PVC (1/4 x 5")
1
1
26
F,G
1081276
Control Panel Only
1
1
27
A - Includes Tubing, Check Valve, Elbow and Tie Wrap.  
B - Knob is black with silver "swish".  Used on Flowmeters with a Slotted Head Screw on top.  
C - Knob is silver with black "swish".  Used on Flowmeters with an Indented Phillips Head Screw on top.  
D - When replacing Flowmeter Assembly Part #1135961 in units built "Before 4/06," it is required that the Patient Outlet 
Pressure be increased to 9psi. Contact Invacare Technical Support at 1-800-832-4707 for more details.  
E - Flowmeter 1128739 is no longer available, refer to Part #1135961 for replacement.  
F - "After 7/19/06" the location of the HEPA Filter has changed. The HEPA Filter is now located inside the cabinet.  
G - For use with Control Panel Assembly "After 7/19/06."  
H - For use with Control Panel Assembly "Before 7/20/06."  
NOTE:
 
46
To order call toll free 1-800-333-6900, or www.invacare.com
Form No. 93-38