Panasonic J-HD1400P Manuale Utente

Pagina di 68
63
Error messages 
(continued)
<Note>
Consult your dealer if the error message display persists even after the unit has been restarted.
Error messages (continued)
Monitor display
Description
Corrective action
VTR 
operation
E-55
UNLOAD ERROR
If the tape has not been taken up during unloading, this error 
number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-57
S-FF/REW 
TIMEOVER
If the start or end processing operation is not completed, this error 
number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-59
DRUM ROTA TOO 
SLOW
If the cylinder motor speed is abnormally low, this error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-60
DRUM ROTA TOO 
FAST
If the cylinder motor speed is abnormally high, this error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-61
CAP ROTA TOO 
SLOW
If the capstan motor speed is abnormally low, the error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-64
S REEL ROTA TOO 
FAST
If the supply reel motor speed is abnormally high, the error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-67
T REEL ROTA TOO 
FAST
If the take-up reel motor speed is abnormally high, the error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-69
T REEL TORQUE 
ERR
If excess torque being applied to the take-up reel motor is detected, 
the error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-70
S REEL TORQUE 
ERR
If excess torque being applied to the supply reel motor is detected or 
an abnormal current flowing to the current detection resistor is 
detected, this error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-71
CAP TENSION 
ERROR
If abnormal tension at the supply side is detected in the capstan 
mode, the error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-72
REEL TENSION 
ERROR
If abnormal tension at the supply side is detected in the reel mode, 
the error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-73
REEL DIR 
UNMATCH
If the take-up reel motor has rotated in the reverse direction, this 
error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-74
DRUM TORQUE 
ERROR
If excess torque being applied to the cylinder motor is detected, this 
error number flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-78
M-IF COMM ERROR
If a problem has been encountered in communication between the 
servo microcomputer and mechanism relay board, this error number 
flashes on the display.
Set the POWER switch to OFF 
and then to ON again.
STOP
E-bA
BATTERY
This appears when the input DC voltage has dropped below the 
undercut voltage.
Check the output voltage of the 
equipment supplying DC 
power.
STOP