Excell Precision Counting Scale Manuale Utente

Pagina di 46
  
EXCELL PRECISION CO., LTD
.                                     
 
Counting                                                                                                                                          ZSME200000003 
28 
4-2-3 Weight Preset 
The scale can store a Hi Limit unit weight value. The scale will make a warning 
beep and the unit weight window will display a blinking   
 
 
 
 
 
 
   
if the unit weight is over the Hi limit value stored. 
 
Set the Hi Limit value for unit Weight
 
         
Œ Press    Q
’TY PST    key whether the scale has object on the weigh pan or not. 
→0←
 3
 
 
 
 
         
 
 
 
 
 
 
                             
 
Stable
 
3
             
 
 
 
 
       
                                                                                                                                    Latest Preset Value 
 
         
• Enter a desired Hi Limit value.    Use    CE    key to correct the value entered. 
→0← 
3
  
 
 
         
 
 
 
 
 
                 
 
 
 
Stable 
3
           
 
 
 
 
                                                                                    Hi Limit Value Entered         
The unit and the decimal points for the high limit value entered are the same as the value 
previously preset on the weight display. 
 
         
Ž Press    UNIT W.T.    key.    Use    CE    key to correct the value entered. 
→0← 
3
  
 
 
         
 
 
 
 
 
                 
 
 
 
Stable 
3
           
 
 
 
 
         
• Press    Q
’TY PST    key, the scale will return to counting mode. 
→0← 
3
  
 
 
                 
 
.
 
 
 
                             
 
Stable 
3
                       
 
 
 
Clear the Hi Limit unit weight and quantity values
 
To clear the Hi Limit unit weight or Quantity preset enter 
“0” as the value in the 
appropriate entry field.