FUNCTION
POSSIBLE CAUSE
REMEDY
9.00
BARRIER WILL 
NOT OPERATE 
UP OR DOWN 
WITH REMOTE 
OR OVERRIDES
9.11  Bad circuit breaker
9.12  Poor plug connections
)DXOW\EDUULHUDFWXDWRUPRWRURU
         actuator out of adjustment
9.14  Bad power and ground
Check for proper operation of Below Stow switch.
Remove weight from platform.
Check harness connectors A1 and A2, E1, N1,
1()DQG)&KHFNSRZHUDWPRWRU$G-
just or replace actuator if necessary.
See 1.00
10.00
BARRIER
OPERATES WITH 
OVERRIDES BUT 
WILL NOT GO UP 
WITH REMOTE
10.11  Barrier Down LED (D29) 
           not illuminated
Check Barrier Down switch for proper operation 
with LED on P.C. board.  Replace or adjust as 
necessary.
11.00
BARRIER
OPERATES WITH 
OVERRIDES BUT 
WILL NOT GO 
DOWN WITH 
REMOTE
11.11  Ground sensor LED (D23) 
           not illuminated
11.12  Below Stow LED (D24) 
           not illuminated
)XOO2XW/(' ' 
           not illuminated
Check Pressure Transducer.  Replace or adjust 
as necessary.  See Ground Sense Calibration on 
page 5.
Check Below Stow switch for proper operation.
Replace or adjust as necessary.
&KHFN)XOO2XWVZLWFKIRUSURSHURSHUDWLRQ
Replace or adjust as needed.
Troubleshooting Diagnosis Chart
12.00
SWITCHES
DO NOT 
ACTIVATE 
LED(S)
12.11  Improper terminal block wiring
12.12  No power going to switches
)DXOW\ZLULQJ
)DXOW\FRQQHFWLRQV
Check terminal block for correct wiring 
FRQÀJXUDWLRQ
Check power on connector A1, pins 1 and 2.
Check continuity of wires from switches to 
connector A2.
Check for proper connections on each switch and 
on each connector on the harnesses.  Replace 
contact if necessary.  See diagram on following 
page.
13.00
DOORS
DO NOT 
OPEN
)DXOW\ZLULQJ
Check for proper wiring to door openers.
14.00
DOORS
DO NOT 
CLOSE
)XOO2XW/(' ' LOOXPLQDWHG
           and Below Stow LED (D24) 
           not illuminated
14.12  Lift Out LED (D25) illuminated
Lift is out but not below stow level.
Lift not stowed fully.  Adjust Lift Out switch.