E-80
Specifi cations
Accuracy at normal temperature: ± 15 seconds a month (with no signal calibration)
Timekeeping: Hour, minutes (hand moves every 10 seconds), seconds, day, day of the week
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 29 city codes and Coordinated Universal Time); 
Daylight Saving Time (summer time) / Standard Time
Time Calibration Signal Reception: Auto receive up to six times a day (5 times a day for the Chinese 
calibration signal; Remaining auto receives cancelled as soon as one is successful); Manual 
receive
Receivable Time Calibration Signals: 
Mainfl ingen, Germany (Call Sign: DCF77, Frequency: 77.5 kHz); Anthorn, England (Call Sign: 
MSF, Frequency: 60.0 kHz); Fukushima, Japan (Call Sign: JJY, Frequency: 40.0 kHz); Fukuoka/
Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz); Fort Collins, Colorado, the United States 
(Call Sign: WWVB, Frequency: 60.0 kHz); Shangqiu City, Henan Province, China (Call Sign: 
BPC, Frequency: 68.5 kHz)
Compass: 20 seconds continuous reading; North indication by hand; Calibration (bidirectional, northerly); 
Manual reading
Altimeter:
Measurement range: –700 to 10,000 m (or –2,280 to 32,800 ft.) without reference altitude
Display range: –3,000 to 10,000m (or –9,840 to 32,800 ft.)
 
Negative values can be caused by readings produced based on a reference altitude or due to 
atmospheric conditions.
Measurement unit: 10 m (or 40 ft.)
Other: Calibration; Manual reading
E-81
Barometer:
Measurement range: 260 to 1,100 hPa (or 7.7 to 32.5 inHg)
Display unit: 1 hPa (or 0.1 inHg)
Other: Calibration; Manual reading; Barometric pressure differential indicator
Thermometer:
Measurement range: –10.0 to 60°C (or 14 to 140°F)
Measurement unit: 0.1°C (or 1°F)
Other: Calibration; Manual reading
Bearing Sensor Precision:
Direction: Within ±12°
 
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
E-82
Pressure Sensor Precision:
Conditions (Altitude)
Altimeter
Barometer
Fixed
temperature
0 to 6000 m
0 to 19680 ft.
± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.
± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
6000 to 10000 m
19680 to 32800 ft.
± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.
Effect of 
variable
temperature
0 to 6000 m
0 to 19680 ft.
± 50 m every 10°C
± 170 ft. every 50°F
± 5 hPa every 10°C
± 0.148 inHg every 50°F
6000 to 10000 m
19680 to 32800 ft.
± 70 m every 10°C
± 230 ft. every 50°F
 Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
 Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14°F to 140°F)
Alarm: Daily alarm
Stopwatch:
Measuring unit: 1 second
Measuring capacity: 11:59' 59"
Measuring modes: Elapsed time
E-83
Illumination: LED (light-emitting diode); Selectable illumination duration; Auto Light Switch (Full Auto LED 
Light operates only in the dark)
Other: Power Saving function; Low battery alert (second hand jumping at 2-second intervals); Auto hand 
position adjustment
Power Supply: Solar panel and one rechargeable battery
Approximate battery operating time: 7 months (from full charge to Level 3) under the following 
conditions:
Alarm: 10 seconds/day
Light: 1.5 seconds (one operation)/day
Second hand operation: 18 hours/day
Time calibration receive: 4 minutes/day
Direction reading: 20 times/month (20 seconds continuous reading)
Readings using the barometric pressure differential indicator: 12 times/day
Climbs: Once (30 altituded readings)/month
Frequent use of illumination runs down the battery. Particular care is required when using the auto 
light switch (page E-71).
L-1
L-2
City Code Table
City Code
City
UTC Offset/
GMT Differential
PPG
(PAGO PAGO)
Pago Pago
–11
HNL
(HONOLULU)
Honolulu
–10
ANC
(ANCHORAGE)
Anchorage
–9
LAX
(LOS ANGELES)
Los Angeles
–8
DEN
(DENVER)
Denver
–7
CHI
(CHICAGO)
Chicago
–6
NYC
(NEW YORK)
New York
–5
SCL
(SANTIAGO)
Santiago
–4
RIO
Rio De Janeiro
–3
RAI
(PRAIA)
Praia
–1
UTC
0
LON
(LONDON)
London
PAR
(PARIS)
Paris
+1
ATH
(ATHENS)
Athens
+2
JED
(JEDDAH)
Jeddah
+3
THR
(TEHRAN)
Tehran
+3.5
DXB
(DUBAI)
Dubai
+4
KBL
(KABUL)
Kabul
+4.5
KHI
(KARACHI)
Karachi
+5
DEL
(DELHI)
Delhi
+5.5
L-3
City Code
City
UTC Offset/
GMT Differential
KTM
(KATHMANDU) Kathmandu
+5.75
DAC
(DHAKA)
Dhaka
+6
RGN
(YANGON)
Yangon
+6.5
BKK
(BANGKOK)
Bangkok
+7
HKG
(HONG KONG)
Hong Kong
+8
TYO
(TOKYO)
Tokyo
+9
ADL
(ADELAIDE)
Adelaide
+9.5
SYD
(SYDNEY)
Sydney
+10
NOU
(NOUMEA)
Noumea
+11
WLG
(WELLINGTON)
Wellington
+12
 Based on data as of December 2010.
 The rules governing global times (UTC offset and GMT differential) and summer time are determined 
by each individual country.
Operation Guide 5242