Grizzly G0756 Manuale Utente

Pagina di 64
-18-
Model G0756 (Mfg. Since 2/13)
Test Run
once  the  preceding  setup  procedures  are  com-
plete, test run your machine to make sure it runs 
properly and is ready for regular operation. 
the  test  run  consists  of  verifying  the  following: 
1)  the  motor  powers  up  and  runs  correctly,  2) 
the  eMergenCy  stop  button  and  chip  guard 
safety  features  work  correctly,  and  3)  the  motor 
rotates  in  the  correct  direction  (machine  is  not 
wired out of phase). 
before starting the drill press, make sure 
you have performed the preceding setup 
instructions, and you have read through the 
rest of the manual and are familiar with the 
various functions and safety features on 
this machine. failure to follow this warning 
could result in serious personal injury or 
even death!
To test run the machine:
1.  Make sure all tools and objects used during 
setup are cleared away from the machine.
2.  Make sure the machine is properly lubricated.
3.  turn  the  Master  power  switch  (figure  11
ON.
5.  Make  sure  the  power  cord  and  wires  have 
slack  between  the  strain  relief  and  terminal 
connections  so  that  they  do  not  bind,  then 
tighten the strain relief to secure the cord.
 Note: 
The strain relief must be tightened 
against the outer jacket of the cord. Avoid 
over-tightening the strain relief or it may 
crush the cord and cause a short.
6.  test  the  strain  relief  to  ensure  it  is  properly 
tightened by pulling the cord from outside the 
box  with  light-to-moderate  force.  When  the 
strain relief is properly tightened, the cord will 
not move inside the cabinet.
7.  install a neMA 15-15 plug on the other end 
of the power cord per the plug manufacturer's 
instructions.
8.  Close  and  secure  the  main  electrical  box 
door.
9.  plug the power cord into a power source with 
a matching receptacle, as specified in 
circuit 
Requirements for 220v on Page 10.
Note:  If you discover during the Test Run that 
the drill press will not operate, or that the spindle 
runs backwards, the drill press may be wired out 
of phase. 
Correcting the phase polarity requires reversing 
the positions where the L1 and L3 wires are con-
nected. Due to the high voltage and risk of serious 
shock involved, we strongly recommend this pro-
cedure only be done by an electrician or qualified 
service personnel.
figure 11. Master power switch.
Master power switch
if,  during  the  test  run,  you  cannot  easily  locate 
the source of an unusual noise or vibration, stop 
using  the  machine  immediately,  then  review 
Troubleshooting on Page 35
if you still cannot remedy a problem, contact our 
tech support at (570) 546-9663 for assistance.