RayTek FA Manuale Utente

Pagina di 67
Options 
Marathon Series FA/FR 
33 
7 Options 
Options are items that are factory installed and must be specified at time of order. The following are 
available: 
•  Fiber optic cable lengths: 1, 3, 6, 10 m (3, 10, 20, 33 ft), 22 m (72 ft) for selected models 
•  ISO Calibration Certificate, based on NIST/DKD certified probes (XXXFR1CERT) 
•  High Temperature Fiber Cable (…H), rated to 315°C (600°F), not available on FA2 models 
•  Laser Sighting (…L) only on FA1A/FA2A and FR1A/FR1B models 
•  Cooling Platform for Electronics Housing (...W) 
 
The High Temperature Fiber Cable excludes Viton coating and IP65 (NEMA‐4) rating! 
7.1 Cooling Platform for Electronics Housing 
The  cooling  platform  for  the  electronics  housing  can  be  used  for  ambient  temperatures  up  to  150°C 
(302°F).  For  an  efficient  cooling  a  water  flow  of  2  l  (0.53  gallons)  per  minute  is  recommended  at  a 
water temperature of 16°C (61°F). 
Mounting hole: Ø 5 mm (0.188); max. fastener head: 8 mm (0.31) 
 
 
Figure 30: Cooling Platform for Electronics Housing