3M 2550 Manuale Utente

Pagina di 70
 32 
78-9000-0192-2 Rev C
F. Expanded Mode
VOL [13] (press up arrow)
When the third ring of the speaker icon is dotted 
or broken and ‘xpnd’ appears below the speaker 
icon as shown, the receiver is in “Expanded” 
mode. This mode is used for pinpointing a 
target cable or pipe. The area of response of the 
receiver narrows, allowing the locator to detect 
very small signal changes. Press the Speaker 
Volume Control [13] ([12] for 2550 locator) key 
to activate the "Expanded" mode.
8. Depth and Current Estimate
Verifying the target path, depth and current can be helpful tools.
•  Pinpoint the cable or pipe being located.
•  Lower the tip of the receiver to the ground and 
press DEPTH [4].
 
− The depth to the target cable or pipe is displayed 
in the units specified in the receiver set up 
menu. The bold current reading is the relative 
current measurement. This reading can be 
compared to the relative current reading that 
alternately flashes with the frequency on the 
transmitter to help identify the target cable/pipe. 
The highest relative current value will be the 
target cable/pipe and will compare closest to the 
transmitter relative current value. The milliamp 
reading is an actual current measurement.
 
− There are two options for measuring depth. 
Live depth is a continuous measurement. 1-Shot 
Depth is an averaging of the depth reading over 
a short period of time. When in 1-Shot mode, 
the unit will average the depth reading for three 
seconds, and then display the result on the 
display. Press DEPTH [4] to alternate between 
the two modes.
 
− Five depth readings can be saved with the time, 
date and relative current measurements.
•  Pressing Mem Select [SK] and then Save [SK] will place each entry in sequential 
order in memory (M1–M5) until five readings have been stored. The unit will 