HP Emulex based Dual Port Fibre Channel HBA 394588-B21#0D1 Dépliant

Codici prodotto
394588-B21#0D1
Pagina di 18
System Unit Node
System Unit Node
System Unit Node
System Unit Node
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with feet/bezel)
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Weight
Weight
Weight
Weight (approximate)
Maximum
Maximum
Maximum
Maximum
60 lb (27.22 kg)
Minimum
Minimum
Minimum
Minimum
47.18 lb (20.41 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Range Input Voltage
Range Input Voltage
Range Input Voltage
Range Input Voltage
100-132 VAC, 200-240 VAC
Rated Input Current
Rated Input Current
Rated Input Current
Rated Input Current
10A (100VAC), 10A (120VAC), 6.1A (200VAC)
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
50 to 60 Hz
Rated Input Power
Rated Input Power
Rated Input Power
Rated Input Power
1000/1056/1205 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
BTU/HR
3490/3680/4150
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL380 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power (per power supply)
Rated Steady-State
Rated Steady-State
Rated Steady-State
Rated Steady-State
800/850/1000 W
Maximum Peak Power
Maximum Peak Power
Maximum Peak Power
Maximum Peak Power
800/850/1000 W
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
Operating
Operating
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude de-rating of 1.8° F per 1000 ft (1.0° C
per 304.8 m) to 10,000 ft (3048 m) no direct
sunlight allowed. Maximum rate of change is 18°
F/Hr (10° C/Hr). Upper operating limit is 10,000
ft (3,048 m) or 70 Kpa/10.1 psia.
System performance may be reduced if operating
with a fan fault or above 30° C.
Non-operating
Non-operating
Non-operating
Non-operating
-22° to 140° F (-30° to 60° C) Maximum rate of
change is36° F/Hr (20° C/Hr). Upper non-
operating limit is 30,000 ft (9,144 m) or
30.3KPa/4.4 psia.
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
101.7° F (38.7° C)
 
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
Operating
Operating
Operating
10% to 90% relative humidity (Rh), 28° C
maximum wet bulb temperature.
Non-operating
Non-operating
Non-operating
Non-operating
5% to 95% relative humidity (Rh), 38.7° C
maximum wet bulb temperature.
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Idle Minimum
Idle Minimum
Idle Minimum
Idle Minimum (Fixed Disk
Drives Spinning)
 
LLLL WAd (BELS)
6.4
LLLL pAm (dBA)
47
Operating
Operating
Operating
Operating Minimum
Minimum
Minimum
Minimum
(Random Seeks to Fixed
Disks)
 
L WAd (BELS)
6.6
LLLL pAm (dBA)
49
QuickSpecs
HP StorageWorks Enterprise File Services Clustered
HP StorageWorks Enterprise File Services Clustered
HP StorageWorks Enterprise File Services Clustered
HP StorageWorks Enterprise File Services Clustered
Gateway G5
Gateway G5
Gateway G5
Gateway G5
Technical Specifications
DA - 12585   EMEA — Version 11 — March 6, 2009
Page 16