Alliance Laundry Systems 70269701R4 Manuale Utente

Pagina di 66
Installation
25
70269701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Before Placing Tumbler into Service
1. Remove or open all panels, and check accessible 
bolts, nuts, screws, terminals and fittings for 
tightness.
2. Replace all panels and guards.
3. Turn on electrical supply to tumbler.
4. Open the supply valve for gas or steam heated 
tumblers.
5. After performing the previous checks, start the 
tumbler by pressing START. (Refer to the 
Operating Manual for detailed instructions.) 
Release the start button and open the loading 
door. The cylinder should stop rotating within 
seven seconds after the door is opened a 
maximum of 2 inches (51 mm). If it does not, 
adjust the loading door switch. Refer to 
Adjustments section.
6. Gas Tumblers: Start the tumbler and check the 
burner flame. Adjust the air inlet shutter as 
required. Refer to the Adjustments section. 
IMPORTANT: The electronic ignition system will 
attempt to light the gas by sparking for the “trial 
for ignition” period. Refer to Table 2
. If gas does 
not ignite within this period, the ignition control 
will go into a safety lockout and the valve will no 
longer open until the control is reset. It may be 
necessary to retry several times to bleed air from 
the gas lines. To reset, open and close the loading 
door and restart tumbler.
If lockout condition persists, check that the manual 
gas shut-off valve is in the “ON” position and that 
the gas service is properly connected. If condition 
still persists, remove tumbler from service.
7. Load the cylinder with a full load of clean rags 
and run to remove oil or dirt from cylinder.
8. Wipe out the cylinder using an all-purpose 
cleaner or detergent and water solution. Refer to 
Figure 5.
Figure 5 
If the tumbler does not meet ANY of the listed 
requirements, remove tumbler from use. Refer to 
Removing Tumbler from Service section.
Required for CE Models Only
Once machine is installed, please be sure to complete 
the following items:
Review and verify machine operation with 
customer.
Leave all literature and a signed Declaration of 
Conformity with customer.
Review machine warranty information with 
customer.
Apply warning sticker on front panel of machine, 
in language appropriate to country of sale 
(included in literature packet).
Location
Prepurge 
Time 
(seconds)
Trial for 
Ignition 
(seconds)
To Reset 
Lockout 
Condition:
CE and 
Australia
18
10
Press reset 
button on rear 
of machine
All others
 1-3
10
Open loading 
door
Table 2 
T452I
T452I