American Dryer Corp. SL31AD-15 Manuale Utente

Pagina di 72
47
SECTION VIII
FACTORY PRESET PROGRAMS
Unless otherwise specified at the time of ordering, the Phase 3 microprocessor controller (computer) has been
preprogrammed by the factory with the following parameters.  Should changes be found necessary, please read
this manual carefully to thoroughly familiarize yourself with the Phase 3 programming characteristics.
Dual Coin
PL01
ºFAr
tInE
Grd
bUZ
Coin
FLS
bCrS
AtIn
 Temperature in Fahrenheit
 Timed mode
 Antiwrinkle guard on
 Antiwrinkle guard buzzer (tone) on
 Coin(s) required to start
 Display will flash in intervals between “FILL”
 and “Amount To Start”
 Bad coin reset
 Accumulative time
PL02
drYL
 Dryness level set at 25
PL03
HIº F
 180º
PL04
HICd
 Temperature - 100º
 Time - 2 minutes
PL05
LOº F
 120º
PL06
LOCd
 Temperature - 100º
 Time - 2 minutes
PL07
PPº F
 150º
PL08
PPCd
 Temperature - 100º
 Time - 3 minutes
PL09
LCdE
 Left coin denomination - 10
PL10
rCdE
 Right coin denomination - 25
PL11
tPLC
 Time per left coin - 4 minutes
PL12
AtSt
 Amount to start - 25
PL13
AFAt
 Amount for additional time - 10
PL14
Adrt
 Automatic dry maximum time - 30 minutes
PL15
GdLY
Gont
 Antiwrinkle guard off delay - 2 minutes
 Antiwrinkle guard on time - 20-seconds
PL16
AGt
 Active Antiwrinkle guard time - 10 minutes