The  following are specific requirements for 
proper and safe operation of your dryer. Failure 
to follow these instructions can create excessive 
drying times and fire hazards.
1.   Do not use plastic flexible duct to exhaust the dryer. Excessive lint can build up 
inside exhaust system and create a fire hazard and restrict air flow. Restricted 
air flow will increase drying time. If your present system is made up of plastic 
duct or metal foil duct, replace it with a rigid or flexible metal duct. Ensure 
present duct is free of any lint prior to installing dryer duct. 
2.   The dryer must not be exhausted into any gas vent, chimney, wall, ceiling or 
any concealed space of a building. The dryer exhaust system MUST be 
exhausted to the outdoors. If the dryer is not exhausted outdoors, some 
fine lint will be expelled into the laundry area. An accumulation of lint in any 
area of the home can create a health and fire hazard. 
3.   Exceeding the length of duct pipe or number of elbows allowed in the 
“Maximum Length” chart can cause an accumulation of lint in the exhaust 
system. Plugging the system could create a fire hazard, as well as increase 
drying times. 
4.   Do not screen the exhaust ends of the vent system. Lint can become caught in 
the screen, increasing drying time. Use an approved vent hood to terminate the 
duct outdoors, and seal all joints with duct tape.
5.  All male duct pipe fittings must be installed downstream with the flow of air. 
6.   Exhaust duct must not be connected or secured with screws or other fastening 
devices which extend into the interior of the duct.
7.   Do not allow combustible material (clothing, draperies/curtains, paper, etc.) to 
come in contact with exhaust system.
 Explosion hazard
Do not install the dryer where gasoline or other flammables are kept or 
stored. Failure to do so can result in death, explosion, fire or burns.
Exhaust Requirements: 
 Use only rigid of flexible metal duct and approved vent hood which has a swing-
out damper hat open when the dryer is in operation. When the dryer stops, the 
dampers automatically close to prevent drafts and the entrance of insects and 
rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5cm) 
clearance between the vent hood and the ground or any other obstruction. 
The vent flap should be able to move freely, although vertical orientation of the 
exhaust system is acceptable. Certain  extenuating circumstances could affect the 
performance of the dryer: 
WARNING