Lg Electronics MFL62512805 Manuale Utente

Pagina di 41
Your  dryer  features  FlowSense
TM 
,  an  innovative 
sensing system that automatically detects blockages 
and restrictions in dryer ductwork. Keeping ductwork 
clean of lint buildup and free of restrictions allows 
clothes to dry faster and reduces energy use.
NOTE:  When  the  dryer  is  first  installed,  this  test 
should  be  performed  to  alert  you  to  any  existing 
problems  with  the  exhaust  duct  in  your  home.  
However, since the test performed during normal 
operation  provides  more  accurate  information  on 
the  condition  of  the  exhaust  duct  than  does  the 
installation test, the number of bars displayed during 
the two tests may not be the same.
To activate the duct condition test :
NOTE: Dryer heating test must be performed before 
proceeding. If heating is normal, perform cooling 
properly. Then perform the duct condition test below:
Press and hold the DAMP DRY BEEP and 
TEMP. CONTROL buttons at the same time. 
While holding these buttons, press POWER 
ON/OFF.
 
The dryer will show lnS in the number display 
to indicate that it is in duct condition testing 
mode.
DUCT CONDITION TEST
Correct Venting
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows 
or bends.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed  
or restricted.
1
2
3
Press the START/PAUSE button.
The dryer will run for 
approximately 2 minutes to test 
for blockages or restrictions to air 
flow in the ductwork. 
If no bars are shown in the display,  
the ductwork is free from serious 
blockages or restrictions.
If all bars are lit, the dryer ductwork  
has a serious blockage that needs to be  
removed immediately.
IMPORTANT: Do NOT interrupt the test cycle!
NOTE: Even if no bars are displayed during the duct 
condition test, some restrictions may still be present 
in the exhaust dust. Refer to pages 14-15 for more 
information.
24