Hasselblad 10026 Manuale Utente

Pagina di 93
Camera body 503CW
Adjustment
June 1998
Revision 1
5:12
Calibration and control of the flash metering system TTL
Control/calibration should be carried out each time the camera has been in for repair.
The tolerance for the flash meter is ±0.3 EV at all settings.
If the Hasselblad Service System 970600 is used, follow the step by step instruction in the
STS user manual.
Note! For calibration work use ISO 100 and LV15.  * (ISO 400/LV12).
If the Test box 902474 is used follow the instruction below.
Calibration requires the following test equipment:
-
Planar CF80 mm lens with controlled diaphragm values.
Deviation max. ±10%.
-
Magazine fitted with Kodak´s grey card.
-
Stabilized DC power supply adjustable to 7.5 volt ± 0.1 volt.
-
Calibrated light box with LV12 and 15.
-
Test box 902474.
-
Non-conductive trimmer, 2 - 2,5mm.
Set-up for calibration:
Lens
Shutter
B or F
Aperture
f 5.6
Camera body
ISO
100
* (400)
Magazine
Fitted with
grey card
Test box 902474
Exposure knob
0
* (+1)
Tolerance knob
Trim
Power supply
Voltage
7.5 ± 0.1v
Light box
LV
15
* (12)
K-factor
1.3
* From camera serial No. from 19ER18271 - See Service info No. 12/98
Link to: VHABSTS