5.  Functions 
••
•  Gain Control 
This camera adopts the manual gain setting method. The factory setting is 0dB (rated image pickup 
state). By adjusting the setting value of the command status register of the camera via the IEEE1394 
serial bus, you can set the gain in 121 steps in the range between −6 to +10dB. However, the amount 
of  gain  change  per  step  is  not  constant  because  of  the  variable  characteristic  of  the  gain  control 
amplifier. 
 
 
••
•  Shutter mode switching 
You can switch the shutter modes by adjusting the setting value of the command status register of the 
camera via the IEEE1394 serial bus. 
 
Normal electronic shutter 
:  Performs exposure control via the internal synchronization signal. 
Random trigger shutter 
:  Random trigger shutter can capture images at any timing using the external 
trigger signal and soft trigger input.  It is effective for image input of moving 
objects and obtaining images of the same timing using multiple cameras. 
 
 
••
•  Normal electronic shutter and Random trigger shutter exposure switching 
You can switch the exposure mode of the electronic shutter by adjusting the  setting  value  of  the 
command status register. This camera supports Trigger mode 0 and Trigger mode 1 of the IIDC1394 
digital  camera  protocol.  You  can  switch  the  exposure  mode  of  the  random  trigger  shutter  by 
adjusting the setting value of the command status register. 
 
FIX mode 
:  The following exposure time can be set via the IEEE1394 serial bus; 
 
  1/100s, 1/250s, 1/500s, 1/1,000s, 1/2,000s, 1/4,000s, 1/10,000s, and  
 
   1/20,000s 
32bit Floating-point format mode  :  
The following exposure time can be set via the IEEE1394 serial bus; 
 
   Exposure time: 10µs ~ 2s 
 
   Exposure time = (-1)** S * (M+1) * 2** (E-127) [sec] 
Sign (S) 
Exponent (E) 
Mantissa (M) 
1bit 
8bit 
23bit 
Pulse width mode(Only Random trigger shutter) 
 
:  The exposure time can be controlled by the TRIG signal pulse width. 
 
   Pulse width   :   1µs ~ 2s 
 
 
••
•  Video output mode 
1/30s non-interlace mode 
All pixels are read in 1/30s, so video image in high vertical resolution can be obtained.