Machine externals specification]]]]] 
(1) Dimensions 
 
 
44mm(W) x 29mm(H) x 70mm(D) (Not including protrusion) 
(2) 
Mass 
   Approximately 
120g 
(3) 
Lens 
mount   C-mount 
 
Notes on combination of C-mount lens: 
- Depending on the lens you use, the performance of the camera may not be brought out fully due 
to the deterioration in resolution and brightness in the peripheral area, occurrence of a ghost, 
aberration and others. When you check the combination between the lens and camera, be sure to 
use the lens you actually use. As for the C-mount lens used combining this camera, the projection 
distance from bottom of the screw should use 9.4mm or less. 
 
 
 
 
 
 
(4) Flange back 
 
 
it is not possible to adjust it. 
(5) Camera body grounding: insulation status 
Conductive between circuit GND and camera body 
 
[[
Operating Ambient conditions]]]] 
(1) Ambient conditions 
- Performance assurance   
Temperature 
  0 
to 
40
°
Humidity  
 
 
10 to 90% (no condensation) 
- Operating assurance 
Temperature 
  -5 
to 
45
°
Humidity  
 
 
90% or less (no condensation) 
- Storage assurance   
Temperature 
  -20 
to 
60
°
Humidity  
 
 
90% or less (no condensation) 
(2) EMC conditions 
 
- EMI (Electro-Magnetic interference) 
EN61000-6-4 conformity 
FCC part15 Subpart B class A conformity 
- EMS (Electro-Magnetic susceptibility)  EN61000-6-2 conformity 
 
Notes on Conformity of the EMC: 
- About the conformity of the EMC standard of this machine, it has guaranteed in the conditions 
combined with the option part of 4th clause. 
When used combining parts other than specification of our company, I ask you to have final EMC 
conformity checked of a visitor with a machine and the whole equipment. 
9.4mm or less
C-mount lens
Bottom of
the screw